89
11.1 SofTWare UPGrade iNSTrUCTioNS
1) Three files should be present on the USB drive. These are T7x Deploy.cab, io.txt, and update.config,.
2) Turn on the treadmill power, and then wait until the standard display picture comes up (Figure A).
3) Insert the USB drive into the "REPROGRAM PORT" of the T7x console back cover (Figure B).
4) After a few seconds, the treadmill will auto run the upgrade processing. The achieved percentage of the scheduled process will be
displayed in the bottom right corner of the display (Figure C).
5) When the update is complete, the display will ask you to remove the USB drive (Figure D). Once the USB drive is removed, the treadmill
will reboot automatically.
6) Press "ENTER, 1, 0, 0, 1, ENTER" to enter into the Manager Mode on the treadmill. Then press the button next to ABOUT (Figure E).
7) Press the button next to VERSION to double check the new software version (Figure F).
8) All of the software version information will now be displayed on the screen (Figure G).
fiGUre a
fiGUre b
fiGUre C
CHaPTer 11: SofTWare UPGrade iNSTrUCTioNS
Содержание T7X-01
Страница 1: ...T 7 x 0 1 T r e a d m i l l S ER V I C E MA N U A l...
Страница 2: ......
Страница 5: ...1 1 1 Serial Number Location Chapter 1 Serial number location...
Страница 36: ...32 Chapter 8 TROUBLESHOOTING 8 1 Electrical Diagram...
Страница 37: ...33 P29 Digital Communication Wire 8 1 Electrical Diagram Chapter 8 Troubleshooting...
Страница 38: ...34 Chapter 8 TROUBLESHOOTING N95 UCB Little Board Wire N97 Hand Pulse Wire 8 1 Electrical Diagrams...
Страница 39: ...35 8 2 MCB LED Instructions Chapter 8 Troubleshooting...
Страница 70: ...66 9 12 Incline Motor RemovaL continued Chapter 9 Part Replacement Guide Figure D Figure E Figure F Figure G...
Страница 95: ...91 NOTEs...