70
9.15 CoNSole Cable rePlaCemeNT
CHaPTer 9: ParT rePlaCemeNT GUide
1) Turn off the power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.13.
3) Take off the cup holder from the right side of the treadmill (Figure A).
4) Use a 6 mm Allen wrench to remove one screw and take off the plastic hand rail (Figure B).
5) Remove the 5 Phillips screws and remove the right side upper plastic cover (Figures C, D, & E).
6) Cut the wire ties and begin to unthread the wire harness (Figures F & G). .
7) Remove the spiral protective wrap from the top and bottom portion of the wire harness (Figures H & I).
8) Attach a pulling wire to the top of the defective console cable (Figure J).
9) Slowly remove the defective console cable starting at the bottom of the machine and pulling it down to the motor compartment (Figure K).
10) Attach new console cable to the pulling wire and gently pull the new cable up through the machine.
11) Once wire is in place, reinstall spiral wrap and wire ties.
12) Auto Calibration must ALWAYS be run after the installation of a new console cable (see Section 3.5).
fiGUre a
fiGUre b
fiGUre C
fiGUre d
fiGUre e
Содержание T7X-01
Страница 1: ...T 7 x 0 1 T r e a d m i l l S ER V I C E MA N U A l...
Страница 2: ......
Страница 5: ...1 1 1 Serial Number Location Chapter 1 Serial number location...
Страница 36: ...32 Chapter 8 TROUBLESHOOTING 8 1 Electrical Diagram...
Страница 37: ...33 P29 Digital Communication Wire 8 1 Electrical Diagram Chapter 8 Troubleshooting...
Страница 38: ...34 Chapter 8 TROUBLESHOOTING N95 UCB Little Board Wire N97 Hand Pulse Wire 8 1 Electrical Diagrams...
Страница 39: ...35 8 2 MCB LED Instructions Chapter 8 Troubleshooting...
Страница 70: ...66 9 12 Incline Motor RemovaL continued Chapter 9 Part Replacement Guide Figure D Figure E Figure F Figure G...
Страница 95: ...91 NOTEs...