61
CHaPTer 9: ParT rePlaCemeNT GUide
9.8 moTor CoNTrol board remoVal (mCb)
1) Turn off the power and disconnect the cord from the machine.
2) Remove the front shroud as outlined in Section 9.1.
3) Cut any wire ties that are secured to the MCB panel (Figure A).
4) Disconnect the wires from the MCB - seven total connections (Figure B).
5) Remove the two MCB mounting screws using a Phillips head screwdriver (Figures C & D) and remove the MCB.
6) Auto Calibration must ALWAYS be run after replacing the MCB (see Section 3.5).
fiGUre a
fiGUre b
fiGUre C
fiGUre d