21
IMPORTANT
Failure to set the reduced rate of the oven burner correctly may
result in performance problems and prevent the oven from
functioning at low temperatures.
Final installation checks
1. Check that all connections are gas tight using appropriate
methods and that the flexible gas hose is positioned
correctly, hanging freely, is not kinked or trapped and is not
in contact with any sharp edges including unfinished
cabinet materials.
2. Check that the supply pressure is correct for the type of gas
being used (Natural Gas 20mbar, Butane 28-30mbar,
Propane 37mbar).
3. Check the correct functioning of all burners at nominal and
reduced rates.
fig. 23
Содержание MR311
Страница 1: ...MR311 Range Cooker Manual for Installation Use and Maintenance GB IE ...
Страница 22: ...22 ...
Страница 23: ...23 ...