18
Natural Gas to LPG conversion
This appliance can be converted from natural gas to propane
operation at a nominal inlet pressure of 37mbar, or butane
operation at a nominal inlet pressure of 28/30mbar. This
conversion must only be carried out by a competent person
(i.e. a Gas Safe registered fitter)
Instructions to fit replacement hob injectors:
1. Disconnect the appliance from the gas and
electrical supplies.
2. Remove burner components and pan supports.
3. Remove the injectors with a 7mm socket spanner and
replace with the corresponding injectors as shown in the
table below.
4. Refit the burner components and pan supports.
5. Regulate the burner minimum flow rates (see page 20).
Instructions to fit replacement oven injectors:
1. Disconnect the appliance from the gas and
electrical supplies.
2. Remove the accessories and the oven floor from the oven.
3. Remove two securing screws at the left hand side of the
burner, marked A (as shown in fig. 20) and move the
burner to the right to allow access to the injector.
4. Remove the injector using a 7mm socket spanner and
replace with the corresponding injector as shown in the
table below.
5. Move the burner back into position and refit the securing
screws A.
6. Set the burner primary air rates (see page 20).
7. Refit the oven floor and accessories.
8. Regulate the oven burner reduced flow rate (see page 20).
fig. 19