Setting up the Range Cooker for
Use
Primary air adjustment for the oven and grill burners
Loosen the adjustment screw A of the air regulation sleeve.
Turn the adjustment sleeve to the position that corresponds to
the type of gas to be used according to the table below.
Tighten the adjustment screw.
When the operation is completed, reassemble the burner and
check the burner is functioning correctly.
Regulation of the hob burner minimum flow rates
1. Natural gas
Light the burner and turn it to the minimum position.
Remove the gas control knob and turn the adjustment
screw at the side of the valve shaft until the required
minimum flame is achieved.
2. LPG
Remove the gas control knob and turn the adjustment
screw at the side of the valve shaft fully clockwise.
Once the above is complete, refit the knob and verify that the
burner flame is stable (the flame must not extinguish when
turning the control knob rapidly between maximum and
minimum position). Leave the control knob at the minimum
position for one minute to check the flame failure device
function. The flame should not extinguish. Repeat this process
for all hob burner controls.
Regulation of the oven burner reduced flow rate
Light the burner and allow the oven to heat up to maximum
temperature. Remove the oven burner control knob and turn
the adjustment screw until the required minimum flame is
achieved, normally 3-4mm flame height. Refit the knob and
verify that the burner flame is stable (the flame must not
extinguish when turning the control knob rapidly between
maximum and minimum position).
fig. 20
fig. 21
fig. 22
Correct flame
Flame faulty in
primary air
Flame with excess
primary air