degradation of regulaiton that would occur due to the voltage drop in the leads between the
power supply and the load.By connecting the supply for remote voltage sensing,voltage is
sensed at the load rather than at the supply’s output terminals.This will allow the supply to
automatically compensate for the voltage drop in the load leads and improve regulation.
+
,
-
:
output terminal,the same as front pane output terminals
S+,S-:
Remote sensing terminal
Disable remote sense function:
1. Use the standard shorting clip which has been installed before leave the factory.Or you
can also use wires to short
“
S+” and
“
+”,”S-“ and “-“..
2. Connect output
“
+” and
“
-“ to the load input teminals
“
+” and
“
-“.
Enable remote sense function:
1. Remove the shorting clip between “S+” and “+”,”S-“ and “-“.
2. Connect output
“
+” and
“
-“(front panel) to the load input teminals “+” and “-“.
3. Connect “S+” to “+” of the load,”S-“ to the “-“ of the load.
Note:To ensure the system stability, please use twisted-pair cables between sense
terminal and load.