23
22
8.2 lCb ERRoR INdICAToRS - CoNTINUEd
CHAPTER 8: TRoUblESHooTINg
CHAPTER 8: TRoUblESHooTINg
8.3 ERRoR CodE TRoUblESHooTINg - 01AC
ERRoR CodE 01AC
1) SyMPToM:
a. 01AC - Electro magnet (ECB) over current.
2) SolUTIoN:
a. On standby mode, measure the resistance on ECB1 and ECB2. Please check the ECB extension cable connection at the LCB (pins 1 &
3 for ECB1, pins 2 & 4 for ECB2), there should be between 12.8 ~ 14.2 ohms. (Figure A)
- If the ECB resistance is out of the range, replace the ECB.
- If the ECB resistance is within the range, replace the LCB.
b. Check the gap of ECB1 and ECB2. There should be a gap of .5mm between the ECB and the flywheel.
- Adjust the gap as shown in Section 9.16.
fIgURE A
lEd STATUS
dESCRIPTIoN
LED1
LCB status (blinking: OK).
LED2
Start or Stop( bright: start )
LED3
Safety stop ( bright: action )
LED4
Safety Key action status ( bright: trigger )
LED5
LCB Error status
LED6
UCB and LCB connection status (blinking: OK)
Status lEd
---------------------------------------------------------------------------------
Firmware definition
-
----------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Hardware definition
-
----------------------------------------------------------------------------------
lEd STATUS
dESCRIPTIoN
LED7
MCU power lamp
LED8
Electro-magnet device 2 PWM lamp
LED9
Electro-magnet device 2 fan lamp
LED10
Electro-magnet device 1 PWM lamp
LED11
Electro-magnet device 1 fan lamp
LED12
DC brake release lamp
LED13
DC 26V lamp
D12
Safety switch power lamp
D35
RPM lamp
D8
Positioning sensor lamp
D15
DC 12V lamp