b
2.5mm
3mm
1
2
3
20mm
b
3mm
c
c
a
STAGE 10
This stage is describing checking that the Top track and Bottom track are concentric.
a.
It is important for the smooth operation of a curved enclosure that the top track and bottom track curvatures are concentric. Check
the concentricity by carefully placing a long 2m level between the outside face of the top and bottom track in the 3 positions shown and
check for vertical. Vertical will indicate that the curvatures are matching. Protect the top and bottom tracks from scratches with masking
tape on the face of the level to prevent metal to metal contact.
b.
If not vertical then adjustment may be required to the top track position via the adjustment in the top of the wall mount and wall
adjuster in the top track. Adjusting these will move the top of the fixed glass panels and clamping positions outwards or inwards as
required. It may be necessary to move the wall adjuster plate horizontal position using the slot in the base of the part. Stage 9b.
c.
The track position can also be moved outwards or inwards by carefully tapping the wall mounts out of vertical via the slotted holes in
the wall mounts. This will effectively move the fixed glass panels inwards or outwards at the top by the wall. Protect the wall mount
metal surfaces from damage if adjusting by tapping out of vertical.
TOP
TRACK
FLOOR
HORIZONTAL