page 18
PROBLEM SOLUTIONS
ATTENTION – DANGER OF EXPLOSIONS !!!!
It is absolutly
prohibited
used alumatic paper or similer to cover the burner, the pilot unit and the side walls
over the drawer.
Advice it will be damaged the range!
The above cause a wrong combustion and bad gasfire, it
over heat extremly
the unit and a bad function of
the burners will happened.
N°
PROBLEM
CAUSE
REMEDY
A
1
Soup burner
Pilot flame does not ignite
- Gas pipe pilot flame not closed
- Pilot flame clogged
- Pilot flame head clogged
- Pilot flame nozzle clogged
- Has the main gas pipe any
gas?
- Dismantle and clean
(evt. exchange)
- clean with steel brush
(evt. dismantle and clean)
- Pilot flame nozzle (C) replace
2
Burner flame is yellow
- Air regulation on nut required
- Burner is dirty
- Air regulation opening on nut
must be mininimum 15 mm
- Take out, take apart, clean
3
Burner does not burnt
- Gas cock is damagedt
- control evt. exchange
4
Pilot flame burns, but does not
stay
- Thermocouple dirty
- Thermocouple does not produce
voltage in millivolt
- Thermocouple is loose
- Thermocouple magnet on gas cock
defective
- clean with fine steel brush
- take apart and exchange
- again screw into position
- take apart and exchange
B
1
Wok range
Pilot flame does not ignite
- Gas tube pilot flame is leaking
- Gas tube pilotf lame clogged
- Pilot flame head is clogged
- Pilot flame nozzle is clogged
- Security armature defective
- has main gas pipe any gas?
- take out and clean
(evt. exchange)
- clean with fine steel brush
(take out and clean)
- Pilot flame nozzle (C)
exchange
- Take out and replace
2
Burner flame is yellow
- Air regulation on nut required
- Burner is dirty
- Air regulation opening on nut
must be minimum 15 mm
- Take out, take apart, clean
3
Burner does not burn
- Gas cock defective
- Control evt. exchange
4
Pilot flame burns, but on
releasing securita arm, flame
does not stay
- Thermocouple dirty
- Thermocouple does not give voltage
in millivolt
- Thermocouple is loose
- Thermocouple magnet on gas cock
defective
- clean with fine steel brush
- take apart abd exchange
- again screw into position
- take apart and exchange