The small combustion load of the Combi Wok burner is 4 kW.
This results in the following
flow values
:
Earthgas
H, E (G20)
0,42 m
3
/h
Earthgas
L, LL (G25)
0,49 m
3
/h
Liquid gas
(G30)
0,31 kg/h
The appliance is operated in full combustion with fixed nozzles without adjustment.
The Wok burner has no small combustion adjustment.
It operates gradual from off (out) to in (in).
For the Combi Wok burner and the pilot flame the small combustion quantity is regulated for liquid gas with
ficed nozzles. For earhgas the nozzles are adjusted.
3.
Instruction of Users
The user must be instructed how to operate the appliance. The instruction for use must be kept to the user.
The user must be told that after construction changes in the room, which affects the combustion supply, the
operation control must be carried out.
4.
Operation
4.1
Operation elements
A= Safety tap button for wok burner:
to operate safety system
B= Wok burner gas valve handle:
to open and close the main burner gas supply
C= Pilot gas valve switch:
to open and close the pilot burner gas supply toward
wok range.
E= Security control knob:
to open and close the gas supply toward burner
soup and to arrange the flame (enlarge and down)
4.2
Start up Wok burner
Before operation the main gas cock on the appliance must be opened.
Then press the knob of the safety tap “A“ in and keep the knob pressed in.
With ignition pistol start up pilot flame. After pilot flame burns knob “A“ to remain pressed in for 15 - 20
seconds. If after releasing knob “A“ the pilot flame goes out, you have to repeat the ignition process.
Now turn gas valve handle “B“ anti clockwise to position “ON“, the Wok burner will ignite.
Attention! Do not lean over main burner during ignition process.
The high flame could lead to burns.