background image

page 4

The small combustion load of the Combi Wok burner is 4 kW.

This results in the following 

flow values

:

Earthgas

H, E (G20)

0,42 m

3

/h

Earthgas

L, LL (G25)

0,49 m

3

/h

Liquid gas

(G30)

0,31 kg/h

The appliance is operated in full combustion with fixed nozzles without adjustment.
The Wok burner has no small combustion adjustment.
It operates gradual from off (out) to in (in).

For the Combi Wok burner and the pilot flame the small combustion quantity is regulated for liquid gas with
ficed nozzles. For earhgas the nozzles are adjusted.

3.

Instruction of Users

The user must be instructed how to operate the appliance. The instruction for use must be kept to the user.
The user must be told that after construction changes in the room, which affects the combustion supply, the 
operation control must be carried out.

4.

Operation

4.1

Operation elements

A= Safety tap button for wok burner:
      to operate safety system

B= Wok burner gas valve handle:
      to open and close the main burner gas supply

C= Pilot gas valve switch:
      to open and close the pilot burner gas supply toward
      wok range.

E= Security control knob:
      to open and close the gas supply toward burner
      soup and to arrange the flame (enlarge and down)

4.2

Start up Wok burner

 

Before operation the main gas cock on the appliance must be opened.

 

Then press the knob of the safety tap “A“ in and keep the knob pressed in.

 

With ignition pistol start up pilot flame. After pilot flame burns knob “A“ to remain pressed in for 15 - 20 
seconds. If after releasing knob “A“ the pilot flame goes out, you have to repeat the ignition process.

 

Now turn gas valve handle “B“ anti  clockwise to position “ON“, the Wok burner will ignite.

Attention! Do not lean over main burner during ignition process.
The high flame could lead to burns.

Содержание AHA0005

Страница 1: ...S Se er rv vi ic ce e w w w m a s t r o s h o p c o m Mastro GmbH H serstra e 53 59075 Hamm Germany 49 0 2381 97371 0 49 0 2381 97371 88...

Страница 2: ...nganleitungen MBM NGWR NGTL Inst BedEN doc INSTALLATIONS OPERATION AND MAINTENANCE INSTRUCTION Gas Wok China Ranges Types Wall and free standing ranges Gas Rechaud Types Table ranges AHA0005 AHA0007 A...

Страница 3: ...irections For the installation and adjustment of the appliances as well as for the changes of the gas types an authorized technician must be called Sealed parts by the producer or authorized agent may...

Страница 4: ...H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 IE II2H3 20 28 30 37 IT II2H3 20 28 30 37 LU I2E 20 NL II2L3B P 25 28 30 NO I3B P 28 30 PT II2H3...

Страница 5: ...eration control must be carried out 4 Operation 4 1 Operation elements A Safety tap button for wok burner to operate safety system B Wok burner gas valve handle to open and close the main burner gas s...

Страница 6: ...ner remains operative For longer periods of cut off and in the evening place knob to position O 5 Important Notice The appliance is for commercial use and should be operated by qualified staff During...

Страница 7: ...aper since corrosion could occur also on stainless steel Pay attention that main burner and pilot flame are not dirty If required burner must be cleaned with non agressive detergents The appliance may...

Страница 8: ...ional cases may only be done by the service engineer Sealed parts of the producer may not be touched by the service engineer If apart from the listed works other reparis should be required same should...

Страница 9: ...8014 S 3 2 Primary air control assy CH 8000 S 3 3 Injector for burner CH 2830 3 4 Safety device CH 3713 1 5 Burner valve CH 2006 1 6 Thermocouple WT 3890 1 7 Pilot burner DBL WT 3851 1 8 Handle shaft...

Страница 10: ...oup burner Del N Description Parts N Quantity 1 Burner assy CH 8020 S 1 2 Primary air control CH 8000 S 1 3 Injector for burner CH 4363 1 4 Security tap WT 3875 1 5 ABS knob valve WT 3602 1 6 Thermoco...

Страница 11: ...page 10 Components water system 03 Del N Description Parts N Quantity 1 Water cock GS 2305 2 3 2 Water flow out GS 3910 1 2 3 Sprayer Pipe 1 2...

Страница 12: ...not stay Thermocouple dirty Thermocouple does not produce voltage in millivolt Thermocouple is loose Thermocouple magnet on gas cock defective clean with fine steel brush take apart and exchange agai...

Страница 13: ...page 13 CONVERSION INSTRUCTION Gas Wok China Ranges Types Wall and free standing ranges Gas Rechaud Types Table ranges AHA0005 AHA0007 AHA0006 AHA0008 AHA0010 AHA0009...

Страница 14: ...20 50 BE II2E 3 20 25 28 30 37 CH II2H3B P 20 50 DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 ES II2H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 I...

Страница 15: ...les without prior adjustment The Wok burner has no small combustion adjustment Same is regulated gradual from OFF out to ON in The Combi Wok burner and the pilot flame are operated for liquid gas for...

Страница 16: ...tion adjustment For the Combi Wok burner soup burner the small combustion adjustment must be regulated to 4 kW for earthgas The nozzle bore in the small combustion nozzle is 50 mbar and 30 mbar To reg...

Страница 17: ...e is an opening of 15 mm see drawing In case of a nozzle change C pay attention that the diameter is not changed If necessary a new adjustment must be done There after nut mother B to be sealed with l...

Страница 18: ...not stay Thermocouple dirty Thermocouple does not produce voltage in millivolt Thermocouple is loose Thermocouple magnet on gas cock defective clean with fine steel brush take apart and exchange agai...

Отзывы: