page 15
The small combustion adjustment for the Combi Wok burner is 4 kW.
This result in the following
flow values
:
Earthgas
H, E (G20)
0,42 m
3
/h
Earthgas
L, LL (G25)
0,49 m
3
/h
Liquid gas
(G30)
0,31 kg/h
9.3
Nozzle data table
Gas typet
Pressure
(mbar)
Wok burner
Ø (mm)
Soup burner
full comb. small comb.
Ø (mm) Ø (mm)
Pilot flame
Ø (mm)
Earthgas E G20
20; 20/25 3 x 2,35
2,35
adjustable
adjustable
Earthgas LL G25
20
3 x 2,60
2,60
adjustable
adjustable
Earthgas
L G25
25
3 x 2,50
2,50
adjustable
adjustable
Liquid gas B/P G30
28 - 30
28 - 30/37
3 x 1,60
1,60
1,00
0,20
Liquid gas B/P G30
50
3 x 1,40
1,40
0,90
0,20
The applience is operated in full combustion with fixed nozzles without prior adjustment.
The Wok burner has no small combustion adjustment. Same is regulated gradual from OFF (out) to ON (in).
The Combi Wok burner and the pilot flame are operated for liquid gas for small combustion with fixed
nozzles, for earthgas same has to be regulated.
9.4
Nozzle change Wok burner
Remove fixing screw (1). Pull burner with gas
pipe out (2). Remove mixing chamber by
moving same anti clockwise from the nozzle.
Twist pressure ring (4) anti clockwise from
the nozzle. Pay attention that the pressure
spring is not lost.
Turn now the nozzle from the gas pipe and
then replace a nozzle according to the nozzle
data table for the required gas type into the
unit. The nozzle must be fixed with a non-
hardening sealing tape.
Then replace the burner by following
instructions in
opposite direction. Pay
attention also to “primary air adjustment“.