5 MASTERBUS FUNCTIONS
5.1 MASTERBUS
MENUS
This chapter describes the MasterBus functions
available with the Digital DC.
Where mentioned, X ranges from 1 to 10 referring to
a specific channel. 10 channels are available.
Menu
Description
Default
Range
Monitoring
Device state
State of the Digital DC. One state is alarm. See
alarms
for
more information.
On On,Stand
by,Alarm,
Disabled
Channels X
Switch On/ Off a specific channel of the unit. Last means the
channel will retain its state before the Digital DC was
switched Off.
On
On, Off, Last
Reset all
alarms
Reset MasterBus alarms in all channels.
Alarms
Alarm status
X
Alarm state of channel X.
Overload
means a current is drawn
that exceeds the software fuse setting.
Hardware fuse
: the
fuse in channel X has blown or the channel voltage is too
low.
Minimum current
: A current below the minimum current
set is detected.
No alarms No alarms,
Overload,
Hardware fuse,
Minimum current,
System temperature alarm state.
Temperature high
: temperature warning,
Temperature
critical
: Device shut off due to overheating.
Tempera-
ture
normal
Temperature
normal, high,
critical
System
Battery Low
means once the voltage of the supply battery
(bank) has dropped below 10V (20V) in a 12V (24V) system
for more than 30 seconds, an alarm will be raised. The alarm
stops as soon as the battery voltage is higher than 11 (22) V
in a 12 (24) V system for more than 30 seconds.
No alarms
No alarm, Battery
low
Configuration
Device
Language
Language setting of the Digital DC. NOTE: the language of
the display may be different from this setting.
English See
Specifications
section 10.1.
Name
Name of your Digital DC in the MasterBus system. If you
have more than one unit you should change names.
DSD DC
Switching
Any name with
maximum 12
characters.
Events
locked
Check box to disable event configuration on the device.
Operable by installer only (log in required).
Un-
checked
Unchecked,
Checked
Logics
locked
Check box to disable logic block configuration on the device.
Operable by installer only (log in required).
Un-
checked
Unchecked,
Checked
Low bat
alarm
See
Alarms
(log in required for alarm adjustments).
Disabled
Disabled, 12V, 24V
Factory
settings
Option to reset the Digital DC to factory settings (log in
required).
System
MasterBus
power
Option for setting the Digital DC to power other MasterBus
devices.
On On,
Off
Channel X
X ranges 1 to 10
Config.
locked
Option to lock configuration of this channel. Unlocked
Unlocked,
Locked
Mode
Select the way channel X should act.
8 different modes are available,
Disabled
being the simplest
and
Manual
the most sophisticated.
Conven-
tional
See section 5.2