4 MASTERBUS 

 

4.1 

WHAT IS MASTERBUS? 

All devices that are suitable for 
MasterBus are marked by the MasterBus 
symbol. 

 
MasterBus is a fully decentralized data network for 
communication between the different Mastervolt 
system devices. This CAN-bus based 
communication network has proven itself as a 
reliable bus-system in automotive applications. 
MasterBus is used as power management system 
for all connected devices, such as the inverter, 
battery charger, generator and many more. This 
gives the possibility for communication between the 
connected devices, for instance to start the 
generator automatically when the batteries are low. 
 
MasterBus reduces complexity of electrical systems 
by using UTP patch cables. All system components 
are simply chained together. Therefore each device 
is equipped with two MasterBus data ports. When 
two or more devices are connected to each other 
through these data ports, they form a local data 
network, called the MasterBus. The results are a 
reduction of material costs as only a few electrical 
cables are needed and less installation time. 
 
For central monitoring and control of the connected 
devices Mastervolt offers a wide range of panels 
which show full status information of your electrical 
system at a glance and a push of a button. Three 
different panels are available, from the MasterView 
Easy up to the full colour MasterView System panel. 
All monitoring panels can be used for monitoring, 
control and configuration of all connected MasterBus 
equipment.  
 

New devices can be added to the existing network in 
a very easy way by just extending the network. This 
gives the MasterBus network a high degree of 
flexibility for extended system configuration, not only 
today, but in the future as well! 
Mastervolt also offers several interfaces, making 
even non-MasterBus devices suitable to operate in 
the MasterBus network. For direct communication 
between the MasterBus network and a product 
which is not from Mastervolt, the Modbus interface is 
recommended. 
 

CAUTION: Never connect a non-
MasterBus device to the MasterBus 
network directly! This will void warranty of 
all MasterBus devices connected. 
 

 

4.2 

EVENT BASED COMMANDS 

With MasterBus each device can be configured to 
initiate an action at another connected device. This 
is done by means of event based commands, see 
chapter 5 for explanation. 
 
An event is a 

condition

 to be met at which you want 

another device

 to perform a 

task

. In chapter 5 the 

Events are explained.  
 
 

Содержание Digital DC 10x10A

Страница 1: ...tal DC 10x10A MasterBus DC Switching Device MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2010 Mastervolt v 1 6 Octob...

Страница 2: ...atus signal MasterBus menus Monitoring menu History menu to keep track of data Configuration menu to enter Digital DC 10x10A settings Alarm menu which shows an Overload and No Load situation of a chan...

Страница 3: ...ions 12 5 4 Wire check 13 5 5 Event configuration 14 5 6 MasterBus Event data 14 5 7 MasterBus logical blocks 15 5 8 Dimming 18 5 9 Event examples Switches 18 6 INSTALLATION 19 6 1 Things you need for...

Страница 4: ...his manual at a secure place 1 2 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place wh...

Страница 5: ...other than mentioned in point 2 is not considered to be consistent with the intended purpose Mastervolt is not liable for any damage resulting from the above 2 3 ORGANIZATIONAL MEASURES The user must...

Страница 6: ...Bus position MasterBus controls up to 10A of the output Manual override Always On Hardware fused Manual override Always Off WARNING Manual Override overrides light voltage settings refer to sections 5...

Страница 7: ...ntrol of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glance and a push of a button Three different panels are avail...

Страница 8: ...network Do not make ring networks The electric power for the network is supplied by the connected MasterBus devices At least one device in the network should have powering capabilities see specificat...

Страница 9: ...k has dropped below 10V 20V in a 12V 24V system for more than 30 seconds an alarm will be raised The alarm stops as soon as the battery voltage is higher than 11 22 V in a 12 24 V system for more than...

Страница 10: ...ting see section 3 2 Application navigation lights and ceiling lights 5 2 3 Light 24V See light 12V now for 24V lighting At a voltage supply of 12V the Light 24V mode is not convenient 5 2 4 Switched...

Страница 11: ...low value can be set in this mode See also section 5 3 8 5 2 10 Always On In Always On the channel does not switch off provided the hardware fuse current is not exceeded Application radio memory refri...

Страница 12: ...DC was switched Off Disabled channel is not enabled power up Last Off On Last Disabled Intensity Voltage as percentage of the maximum output voltage 100 0 100 Maximum voltage Fixed maximum channel out...

Страница 13: ...ch Convenient are the Switch Input 3 or 4 with LED buttons The Digital DC is able to illuminate a button LED when the load is switched On and it is working correctly This is possible only after config...

Страница 14: ...vice you chose The command can be a section of the device to perform a task for example Channel 1 if the Digital DC is the target Select Selectable targets are system dependent Event 1 data Data trans...

Страница 15: ...e function Disabled must be selected when the logical block is not used 5 7 2 Logical truth table For each of the three logical block sources one of next options can be chosen True 1 and False 0 are f...

Страница 16: ...ht until it reaches the end switch When the end switch is closed 1 the drive must stop Shown are three situations The roof is in open position the end switch is open 0 The roof is being closed the end...

Страница 17: ...Function Source 1 Source 2 Source 3 Result description AND Close roof End sw open True Only if the motor switch is on Close roof AND the End switch is open Roof is closed is TRUE In the next event Roo...

Страница 18: ...Off 0 5 sec Dimming till button release 5 9 EVENT EXAMPLES SWITCHES 5 9 1 Event example 1 Main switch In this example the main system switch Switch 4 disables two Digital DC s Event configuration exam...

Страница 19: ...se isolated tools Materials Digital DC 10x10A Up to ten fuses together maximum 100A per Digital DC See section 3 2 10 2 fuses 15A included see figure 1 MasterBus cable Terminator for MasterBus One tra...

Страница 20: ...n MasterBus power is needed 1 DC In positive line 2 DC In negative line 3 Hardware fuses with two positions each 4 DC Output 1 5 Positive at the left Negative at the right For connecting the cables se...

Страница 21: ...Digital DC input 6 7 MASTERCONNECT The Digital DC 10x10A belongs to the MasterConnect range These devices link to each other on the DC connectors directly by pushing them together and bolt them See f...

Страница 22: ...on is pressed The reading light can now be switched On and Off by pressing the button shortly If configured long button presses let the light grow and dim alternately 7 2 SYSTEM EXAMPLE 1 CAMPER Figur...

Страница 23: ...Off means the channels outputs are disabled except for the Always On outputs These outputs see also section 3 2 will stay active even when the Digital DC is disabled useful for a radio memory or refr...

Страница 24: ...mble MasterBus cables Delivery includes 100m 330ft UTP cable 50 pcs modular jacks and crimping tool 77050100 100m 330ft MasterBus cable 77050200 50 pcs MasterBus connectors 77030900 Digital Input 7703...

Страница 25: ...ide the 12V light voltage will change to the system voltage this can be 24V Make appropriate settings and change fuse position to Normal Position Wrong output voltage measured in one channel of Digita...

Страница 26: ...e Digital DC 10x10A Unlimited MasterBus powering capacity Yes high powering Power consumption off board situation 2 mA 12V 2 mA 24V Communication isolation Galvanic Software layer MasterBus proprietar...

Страница 27: ...7020400 Digital DC 10x10A Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonised standards have been applied Generic emissio...

Страница 28: ...Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 Email info Mastervolt com...

Отзывы: