The
Digital DC 10x10A
is a MasterBus based input
and output module. It controls maximum 10 fused
DC channels with currents up to 10A or maximum
100A when the 10 channels are linked.
It provides the MasterBus network (see chapter 4)
with information about the state of the fuses and
devices. A MasterBus display enables you to view
this information, see section 3.3.
Input
MasterBus signal, generated by:
•
Digital
Input;
•
Switch Input 3;
•
Switch
Input
4;
•
MasterView
Easy
display;
•
PC with MasterBus USB interface;
•
Any other MasterBus device connected, via
MasterBus events.
•
Electric signal, generated by an electric On/Off
switch connected to the Digital DC directly.
Output
•
Electric current up to 10A with software fuse;
•
MasterBus output status signal;
MasterBus menus
•
Monitoring
menu;
•
History menu to keep track of data;
•
Configuration menu to enter Digital DC 10x10A
settings;
•
Alarm menu which shows an Overload and No
Load situation of a channel and what fuse has
possibly blown;
•
Event
menu
Read out device
For installing and adjusting the Digital DC a read out
device is necessary. For example:
•
MasterView
Easy
MkII;
•
MasterAdjust PC software (via USB interface)
Communication LED
The LED (figure 1, point 2) has 5 modes, see table.
LED Mode
State
Meaning
Off
-
No power available
One short blink every 10 sec
Disabled
DC available at input
Two short blinks every 10 sec
Disabled
One or more outputs have been set to Always on
One short blink every 1 sec
Enabled
ALARM
On continuously
Enabled
Normal use
The Digital DC 10x10A only functions when MasterBus configured!
Figure 1: Digital DC 10x10A
1. DC input
2. Communication LED
3. Functionality determined
by fuse positions
4. Channels for DC output
or signal input
5. MasterBus connectors