Master UNCO Скачать руководство пользователя страница 10

Dear Customer, Thank you for purchasing a MASTER spa product . This manual describes the operations necessary for the proper installation of the motor with electronic limit
switches model UNCO. The tubular motor with electronic limit switches UNCO series are suitable for handling the main types of roller, particularly if manual or automatic hooks are
present near the low limit switch.
The technical characteristics are provided on the label stuck on motor. These devices have not been studied for a continuous working. Any other use is improper and forbidden and it
could void manufacturer’s warranty. The manufacturer cannot be considered responsible for any damage due to improper, wrong or unreasonable use. The installation of the product
must be done by a qualified technician. At the end of the installation, all manuals must be given to the end user. Keep this manual for future reference!

The technical characteristics of the motor are shown in the label applied to the motor tube. Before installing the motor, it is recommended to copy the technical data (including the full
name of the product) and store them in a safe place. These data may be useful in the event of subsequent maintenance or technical assistance. In addition to the technical data on the
motor tube (depending on the specific power of the motor), the common characteristics of the motor familyUNCO are:

01. TECHNICAL SPECIFICATIONS

MASTER uses packaging recyclable materials. Dispose materials on the proper
containers, complying with the law in force in your locality.
This product may have substances that are polluting for the environment and dangerous
for the health.
At the end of the product life cycle, carefully comply with the waste disposal rules. It is
strictly forbidden to dispose the product on the domestic waste.

Disposal

01. Technical specifications
02. Warnings
03. Installation of offset adapters
04. Electrical connections
05. Installation using the command buttons
06. Installation using a transmitter
07. Electronic control
08. How to memorize/delete a radio device
09. Fine adjustment of upper limit switch
10. Fine adjustment of lower limit switch
11. Modify both the limit switch
12. Favorite position
13. Sun, wind, rain sensors
14. Operation logic of command buttons
15. Test radio
16. Traction on hooks
17. Obstacle on downward
18. Torque reduction
19. Autozero mode
20.Error mesasge and recovery operation
21. Reset

Table of contents

It is advisable

(for example, near police

stations, airports, ports, hospital, etc). A technical inspection is in any case advisable before installing any
radio system in order to identify sources of interference.
Radio systems can be used where possible disturbances or malfunctioning of the transmitter or the receiver
do not cause a risk factor, or if the risk factor is cancelled by suitable safety systems.
The presence of radio device operating on the same transmission frequency (

) can interfere

with the radio receiver of the motor and so reduce the range of the system and limit the functionality of the
installation.

to avoid using radio systems in areas with strong interference

433,42 MHz

Notes on radio systems

USER MANUAL

tubular motor Ø45 mm with electronic limit switch and integrated radio receiver

rev03.1  27.06.2017

UNCO

All rights reserved. All products and technical specifications given in this document are subject to variation without notice.The manufacturer shall not be liable for damage resulting from improper, incorrect or
unreasonable use.

Power supply

: 230 Vac 50 Hz

Stand-by consumption

: < 1W

Min roller diameter

: 50 x 1.5 mm

IP insulation

: I P44

Insulation class

: H

Continuous working time

: 4 minutes

Working frequency

:433.42 MHz

Memorizable transmitters

: 40 (*)

Memorizable wind radio sensors

: 4

Memorizable sun radio sensors

: 1

(*) not including wind/sun radio sensors

02. WARNINGS

02.1 Warnings for safety

02.2 Warnings for installation

02.3 Warnings for use

Incorrect installation can cause serious injuries

Keep these instructions for future maintenance work and disposal of the product

All the product installation, connection,

programming and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws, provisions, local regulations and the instructions
given in this manual

The wiring must comply with current IEC standards. The final electrical system must be created only by the electrician

Some applications require hold-to-run

operation and can exclude the use of radio controls or require particular safety devices

To prevent potentially dangerous situations, check the operating condition of the roller

shutter/awning regularly

The product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are
supervised or given instructions about the product way of use by a person responsible for their safety

Check the automation during the movement and keep people at a safe

distance, until the movement ends

Do not allow children to play with the appliance or with the fixed control devices

Do not operate the blind when maintanance operations are

being carried out (e.g. window cleaning, etc.). If the control device is automatic, disconnect the motor from the power line

Before installing the product, check the compatibility with the associated devices and accessories

Check that the package is intact and has not been damaged in transit

A heavy

knock and the use of unsuitable tools can cause the damage of the external or internal parts of the motor

Do not pierce or tamper with the motor in any way. Do not modify or replace

parts without the manufacturer's permission

Do not carry the motor by the power cable. The product may not be used if the power cable is damaged. Do not try to replace the power

cable

Any screws needed to complete the installation must not come into contact with the motor

The power of the motor must be sufficient for the applied load (check the rated data

shown on the motor)

Some stages of programming and/or normal operation make use of the mechanical stops of the roller shutter/awning. It is essential to choose a motor with the

most suitable torque for the application, considering the actual traction of the roller shutter/awning, and to avoid motors that are too powerful

Use winding rollers that are at least

1mm thick

Leave 1-2 mm of right/left play on the winding roller

Check that the shape and size of the drive pulley and adapter crown correspond to the winding roller used. Adapters,

supports and sundry accessories related to the motor must be chosen exclusively from the MASTER catalogue

If the product is installed at a height of less than 2.5 m from the floor

or from another support surface, the moving parts must be protected with a cover to prevent accidental access. In any case, ensure access for maintenance work

The power cable

must be positioned in such a way that it does not come into contact with moving parts

The power cable of the product is suitable for indoor installation only. If installed outside, place

the cable in a protective tube

If there are several radio appliances in the same system, they must not be less than 1,5m apart

Do not install the product near metal surfaces

Position the buttons within sight of the roller shutter/awning but a long way from its moving parts. Position the buttons more than 1.5 m from the floor

The motors are designed for

residential use; the maximum continuous operating time is 4 minutes

During operation, the motor body becomes very hot, so be careful

The motor contains a self-resetting

thermal cut-out, which stops the motor if it overheats. The motor returns to normal operation when its temperature drops below the safety limit (normally after 5 to 10 minutes)

The

motor must be installed so that it cannot come into contact with liquids and in any case in a position protected from atmospheric agents

The antenna cable carries line voltage. Do not

cut the antenna cable as this would be dangerous. If the antenna cable is damaged, replace the product

For your safety, do not work near the winding roller while the motor is

powered

www.mastermotion.eu

R

When mounting the motor, make sure to curve the power cord in order to reduce the risk of water infiltration!

Содержание UNCO

Страница 1: ...UNCO rev 03 1_27 06 2017 Seleziona la lingua Select the language...

Страница 2: ...effettuate esclusivamente da un tecnico qualificato e competente rispettando le leggi le normative i regolamenti locali e le istruzioni riportate in questo manuale Il cablaggio elettrico deve rispetta...

Страница 3: ...NERO sostituendo di fatto i pulsanti di comando manuale Di conseguenza la centrale domotica deve rispettare le regole di funzionamento dei pulsanti di comando diverse a seconda che i pulsanti di coma...

Страница 4: ...ESA assieme 03 1 2 3 Premi brevemente E il pulsante che MUOVE IL MOTORE IN DISCESA 3 VOLT Il motore inizia a compiere brevi movimenti in salita Attendi arresto automatico oppure arresta manualmente 06...

Страница 5: ...lo interpretato come un fermo il motore si arresta e mantiene il telo in tensione Se l ostacolo rilevato in posizione tale da non poter essere un fermo il motore arresta la manovra di salita e si muov...

Страница 6: ...e FORME per 5 secondi 03 Il motore segnala Memorizzato 01 Premi FORME Trasmettitori ARCO Per memorizzare Per richiamare 01 Porta il motore in posizione preferita 02 Premi brevemente 6 volte STOP e poi...

Страница 7: ...ARCO Trasmettitori FLUTE KUADRO KORT Trasmettitori VISIO Altri trasmettitori 01 Porta il motore in posizione intermedia 02 Premi MENU per circa 5 sec sul display compare la scritta rS 03 Premi 1 volt...

Страница 8: ...sulta il manuale del tuo trasmettitore alla voce MENU RICEVITORE FUNZIONE 13 Ostacolo discesa Numero movimenti Impostazione 1 2 3 4 Funzione non attiva Sensibilit minima Sensibilit media Sensibilit ma...

Страница 9: ...e vedi sezione 21 Se invece il finecorsa superiore stato memorizzato per contatto con una battuta possibile ripristinare manualmente la funzionalit del motore senza essere costretti a resettarlo L ope...

Страница 10: ...installation connection programming and maintenance operations must be carried out only by a qualified and skilled technician who must comply with laws provisions local regulations and the instructio...

Страница 11: ...mand buttons can be connected via a parallel connection The control buttons are subject to the mains voltage and therefore should be properly insulated and protected In the case where the command butt...

Страница 12: ...ogether UP and DOWN 03 1 2 3 Press briefly the button that MOVES THE MOTOR DOWN The motor starts to makes short upward movements 3 TIMES Wait automatic stop or stop manually to set the lower limit swi...

Страница 13: ...ps the fabric in tension If the obstacle is detected in such a position that it can not be a hook the motor stops the upward movement and performs a quick downward movement to free the structure by tr...

Страница 14: ...To memorize To recall 01 Bring motor in the favorite position 02 Press together STOP and FOR ME for 5 seconds 03 Motor performs a signal 01 Press FOR ME ARCO To memorize To recall 01 Bring motor in t...

Страница 15: ...in good time any malfunction of the radio sensor or of the radio communication To modify this parameter 10 1 UTILIZZANDO IL TRASMETTITORE solo Atom e Leg ARCO FLUTE KUADRO KORT VISIO Other transmitter...

Страница 16: ...the desired setting 1 to 4 06 Press STOP The motor signals the new value 1 to 4 movements See the User manual of the transmitter at section RECEIVER MENU Function 13 Obstacle on downward 17 1 HOW TO...

Страница 17: ...DO IL TRASMETTITORE solo Atom e Leg ARCO FLUTE KUADRO KORT VISIO Other transmitters 01 Bring the motor in an intermediate position 02 Press MENU for about 5 sec until rS appears on display 03 Press 1...

Отзывы: