Feed Water Requirements: 

 

1.  The feed water for the PURO PRO must meet the following 

requirements: 

 
2.  A feed water source which does not meet these requirements 

must be treated prior to the PURO PRO system. 

 

Electrical Requirements: 

 
1.  Provide an 115v/60Hz properly grounded dedicated electrical    
     outlet. (It’s very important that the polarity be correct) 

      

Avoid using outlets that are switch controlled.

  

2.  Maximum amperage required is 5 amps. 
3.  Make sure the electrical service provides power 24 hours per day.  
     We recommend installing a

 surge protector 

to protect unit from   

     power surges, which are not covered by warranty.  

 
 
 
 
 
 
 
 
 
 
 
 

Feed Water Condition 

Requirement 

Pressure 

40 psi to 90 psi 

Temperature 

40 to 100 degrees Fahrenheit 

Total Dissolved Solids 

50 to 2000 mg/l 

Hardness 

Less than 4 GPG 

Iron 

Less than 0.1  mg/l 

Manganese 

Less than 0.05 mg/l 

Chlorine 

Maximum 1.0 mg/l 

pH 

4.0 to 10.0 

Содержание PURO PRO 1800 SC Series

Страница 1: ...OPERATION MANUAL PURO PRO 1800 SC Series Modular Reverse Osmosis System MASTER Water Conditioning Corp www masterwater com September 2012 Version...

Страница 2: ...nections 9 10 PURO PRO Power Switch Operation 10 11 PURO PRO Float Switch Operation 11 12 Filling the PURO PRO with Water and Start Up 13 PURO PRO Operation and Maintenance 13 14 Production Data Recor...

Страница 3: ...d Solids TDS from water The system consists in six 6 high performance reverse osmosis membranes The system is designed to operate with a pressurized 40 to 90 psi feed and a vented storage tank for col...

Страница 4: ...be correct Avoid using outlets that are switch controlled 2 Maximum amperage required is 5 amps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge prot...

Страница 5: ...3 Figure 1 Typical PURO PRO Installation...

Страница 6: ...eservative 5 Ensure that the O Ring s on each housing and membrane has Silicone only Lubricant Do not use petroleum lubricants 6 Install two of the membranes in the top row 7 To install the membranes...

Страница 7: ...rane Placing Membrane In Manifold Inserting Membrane Housing Into Manifold 8 Repeat with the second membrane in the middle row 9 Install the remaining membranes using the procedure from steps 7 and 8...

Страница 8: ...6 Figure 2 Manifold Figure 3 Housings Pre Filter Manifold Post Filter Manifold 4 Membrane Manifolds Housing O Ring...

Страница 9: ...O Positioning 1 Wall mount the PURO PRO There are holes drilled into the plastic housing to be used for wall mounting If using the PURO PRO on the ground make sure to place a support under the bottom...

Страница 10: ...nnections Figure 5 1 Pipe Puro Pro into the service lines the inlet is NPT and the outlet is OD tube compression We recommend using an inlet outlet and bypass valve in installation piping for future s...

Страница 11: ...when in the horizontal floating position See Figure 1 2 Connect the float switch to the power box with the electrical connector provided See Figure 6 3 The inlet solenoid is already connected to the...

Страница 12: ...float switch is in the vertical position Whenever the storage tank is full the float switch is in the horizontal floating position the solenoid will be closed PURO PRO Power Switch Operation 1 The pow...

Страница 13: ...is closed power is passed and the solenoid valve is opened allowing the Modular Pro to produce treated water 2 This function can be tested by holding the float adjusting the orientation and listening...

Страница 14: ...12 Low Water Switch On High Water Switch Off WEIGHT METHOD Low Water Switch On High Water Switch Off ANCHOR POINT METHOD WEIGHT DEVICE...

Страница 15: ...sure that the water level is as required Adjust the float rotation point as necessary PURO PRO Operation and Maintenance 1 To ensure proper maintenance it is recommended that a production data sheet b...

Страница 16: ...14 6 If the module frame structure becomes loose tighten the FRP Bolts located at the frame corners...

Страница 17: ...duct Quality Action Taken Product measurement criteria is selected based upon the configuration of the system For example an appropriate criteria may be gallons per hour or inches of tank height per h...

Страница 18: ...have become severely fouled Replace and re start Symptom PURO PRO has greatly reduced production Possible Cause Solution Water pressure is decreased below 60 psi Restore water pressure Drain control...

Страница 19: ...oid has failed Replace inlet solenoid Symptom Storage Tank Overflows Possible Cause Solution Float Switch has failed Replace float switch Inlet Solenoid has failed Replace the inlet solenoid PURO PRO...

Страница 20: ...freezing or hot water All replacement filters and membranes must be Master Water Conditioning filters and membranes or the warranty is void If the unit is altered by anyone other than Master Water Co...

Отзывы: