16 

 

 

Troubleshooting 

 
 

Symptom:

  PURO PURE fails to make any pure water. 

 

Possible Cause 

Solution 

Power supply to PURO PRO has 
been interrupted. 

Determine reason for power 
interruption and correct.   

Water pressure lost. 

Restore water pressure. 

Drain control is closed. 

Review and repeat Start-Up 
procedure. 

Storage Tank is full. 

Recheck when water level decreases. 

Filters and/or membranes have 
become severely fouled. 

Replace and re-start. 

 

Symptom: 

 PURO PRO has greatly reduced production. 

 

Possible Cause 

Solution 

Water pressure is decreased below 
60 psi. 

Restore water pressure. 

Drain control is improperly set. 

Review and repeat Start-Up 
procedure. 

Filters and/or membranes have 
become severely fouled. 

Check and replace prefilter, post filter 
and then membranes until production 
resumes. 

Feed water temperature has 
decreased to below 45 degrees F. 

Raise feed water temperature. 

Feed water TDS has increased to 
over 2000 ppm. 

Consider high-pressure reverse 
osmosis system. 

 

 

 
 
 
 
 

 
 
 

Содержание PURO PRO 1800 SC Series

Страница 1: ...OPERATION MANUAL PURO PRO 1800 SC Series Modular Reverse Osmosis System MASTER Water Conditioning Corp www masterwater com September 2012 Version...

Страница 2: ...nections 9 10 PURO PRO Power Switch Operation 10 11 PURO PRO Float Switch Operation 11 12 Filling the PURO PRO with Water and Start Up 13 PURO PRO Operation and Maintenance 13 14 Production Data Recor...

Страница 3: ...d Solids TDS from water The system consists in six 6 high performance reverse osmosis membranes The system is designed to operate with a pressurized 40 to 90 psi feed and a vented storage tank for col...

Страница 4: ...be correct Avoid using outlets that are switch controlled 2 Maximum amperage required is 5 amps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge prot...

Страница 5: ...3 Figure 1 Typical PURO PRO Installation...

Страница 6: ...eservative 5 Ensure that the O Ring s on each housing and membrane has Silicone only Lubricant Do not use petroleum lubricants 6 Install two of the membranes in the top row 7 To install the membranes...

Страница 7: ...rane Placing Membrane In Manifold Inserting Membrane Housing Into Manifold 8 Repeat with the second membrane in the middle row 9 Install the remaining membranes using the procedure from steps 7 and 8...

Страница 8: ...6 Figure 2 Manifold Figure 3 Housings Pre Filter Manifold Post Filter Manifold 4 Membrane Manifolds Housing O Ring...

Страница 9: ...O Positioning 1 Wall mount the PURO PRO There are holes drilled into the plastic housing to be used for wall mounting If using the PURO PRO on the ground make sure to place a support under the bottom...

Страница 10: ...nnections Figure 5 1 Pipe Puro Pro into the service lines the inlet is NPT and the outlet is OD tube compression We recommend using an inlet outlet and bypass valve in installation piping for future s...

Страница 11: ...when in the horizontal floating position See Figure 1 2 Connect the float switch to the power box with the electrical connector provided See Figure 6 3 The inlet solenoid is already connected to the...

Страница 12: ...float switch is in the vertical position Whenever the storage tank is full the float switch is in the horizontal floating position the solenoid will be closed PURO PRO Power Switch Operation 1 The pow...

Страница 13: ...is closed power is passed and the solenoid valve is opened allowing the Modular Pro to produce treated water 2 This function can be tested by holding the float adjusting the orientation and listening...

Страница 14: ...12 Low Water Switch On High Water Switch Off WEIGHT METHOD Low Water Switch On High Water Switch Off ANCHOR POINT METHOD WEIGHT DEVICE...

Страница 15: ...sure that the water level is as required Adjust the float rotation point as necessary PURO PRO Operation and Maintenance 1 To ensure proper maintenance it is recommended that a production data sheet b...

Страница 16: ...14 6 If the module frame structure becomes loose tighten the FRP Bolts located at the frame corners...

Страница 17: ...duct Quality Action Taken Product measurement criteria is selected based upon the configuration of the system For example an appropriate criteria may be gallons per hour or inches of tank height per h...

Страница 18: ...have become severely fouled Replace and re start Symptom PURO PRO has greatly reduced production Possible Cause Solution Water pressure is decreased below 60 psi Restore water pressure Drain control...

Страница 19: ...oid has failed Replace inlet solenoid Symptom Storage Tank Overflows Possible Cause Solution Float Switch has failed Replace float switch Inlet Solenoid has failed Replace the inlet solenoid PURO PRO...

Страница 20: ...freezing or hot water All replacement filters and membranes must be Master Water Conditioning filters and membranes or the warranty is void If the unit is altered by anyone other than Master Water Co...