Filling the PURO PRO with Water and Start-Up: 
 

1.  Once all hydraulic and electrical connections are completed 

and the power box is plugged into a 120V power source, close 
a feed water inlet valve, and crack it open about ¼. 

2.  Switch the power box switch to ON, and water will enter the 

PURO PRO.  Let the water continue to fill all of the housings at 
this reduced flow rate until water flows freely out the drain. 

3.  Open the feed water inlet valve until the feed water pressure 

gauge is about ½ open. 

4.  The membranes are packaged in preservative material.  This 

fluid should be flushed to drain for at least one hour before 
connection to the storage tank.  

5.  Once this is completed, the system should be connected to the 

storage tank for pure water production. 

6.  Observe the operation of the float switch to ensure that the 

water level is as required.  Adjust the float rotation point as 
necessary. 

                              

PURO PRO Operation and Maintenance: 
 

1.  To ensure proper maintenance it is recommended that a 

production data sheet be established for each system.  A 
Baseline Performance should be established at the initial 
installation.  This Baseline is then compared to subsequent 
production performance at each six-month interval thereafter.  
Significant variances are cause for maintenance activity. 

2.  See page 15 for a recommended production data sheet.  If 

production specifications change more than 20 percent, then 
some action is normally suggested.

 

3.   Normal maintenance activities include replacing the 

membranes. 

4.  The membranes (6) may require replacement every two years.  

This frequency may vary based upon feed water quality and 
upon changes to the production rate of treated water. 

5.  Each time a membrane module is removed, the housing should 

be rinsed with a dilute bleach solution and then fresh water 
before being replaced. 

Содержание PURO PRO 1800 SC Series

Страница 1: ...OPERATION MANUAL PURO PRO 1800 SC Series Modular Reverse Osmosis System MASTER Water Conditioning Corp www masterwater com September 2012 Version...

Страница 2: ...nections 9 10 PURO PRO Power Switch Operation 10 11 PURO PRO Float Switch Operation 11 12 Filling the PURO PRO with Water and Start Up 13 PURO PRO Operation and Maintenance 13 14 Production Data Recor...

Страница 3: ...d Solids TDS from water The system consists in six 6 high performance reverse osmosis membranes The system is designed to operate with a pressurized 40 to 90 psi feed and a vented storage tank for col...

Страница 4: ...be correct Avoid using outlets that are switch controlled 2 Maximum amperage required is 5 amps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge prot...

Страница 5: ...3 Figure 1 Typical PURO PRO Installation...

Страница 6: ...eservative 5 Ensure that the O Ring s on each housing and membrane has Silicone only Lubricant Do not use petroleum lubricants 6 Install two of the membranes in the top row 7 To install the membranes...

Страница 7: ...rane Placing Membrane In Manifold Inserting Membrane Housing Into Manifold 8 Repeat with the second membrane in the middle row 9 Install the remaining membranes using the procedure from steps 7 and 8...

Страница 8: ...6 Figure 2 Manifold Figure 3 Housings Pre Filter Manifold Post Filter Manifold 4 Membrane Manifolds Housing O Ring...

Страница 9: ...O Positioning 1 Wall mount the PURO PRO There are holes drilled into the plastic housing to be used for wall mounting If using the PURO PRO on the ground make sure to place a support under the bottom...

Страница 10: ...nnections Figure 5 1 Pipe Puro Pro into the service lines the inlet is NPT and the outlet is OD tube compression We recommend using an inlet outlet and bypass valve in installation piping for future s...

Страница 11: ...when in the horizontal floating position See Figure 1 2 Connect the float switch to the power box with the electrical connector provided See Figure 6 3 The inlet solenoid is already connected to the...

Страница 12: ...float switch is in the vertical position Whenever the storage tank is full the float switch is in the horizontal floating position the solenoid will be closed PURO PRO Power Switch Operation 1 The pow...

Страница 13: ...is closed power is passed and the solenoid valve is opened allowing the Modular Pro to produce treated water 2 This function can be tested by holding the float adjusting the orientation and listening...

Страница 14: ...12 Low Water Switch On High Water Switch Off WEIGHT METHOD Low Water Switch On High Water Switch Off ANCHOR POINT METHOD WEIGHT DEVICE...

Страница 15: ...sure that the water level is as required Adjust the float rotation point as necessary PURO PRO Operation and Maintenance 1 To ensure proper maintenance it is recommended that a production data sheet b...

Страница 16: ...14 6 If the module frame structure becomes loose tighten the FRP Bolts located at the frame corners...

Страница 17: ...duct Quality Action Taken Product measurement criteria is selected based upon the configuration of the system For example an appropriate criteria may be gallons per hour or inches of tank height per h...

Страница 18: ...have become severely fouled Replace and re start Symptom PURO PRO has greatly reduced production Possible Cause Solution Water pressure is decreased below 60 psi Restore water pressure Drain control...

Страница 19: ...oid has failed Replace inlet solenoid Symptom Storage Tank Overflows Possible Cause Solution Float Switch has failed Replace float switch Inlet Solenoid has failed Replace the inlet solenoid PURO PRO...

Страница 20: ...freezing or hot water All replacement filters and membranes must be Master Water Conditioning filters and membranes or the warranty is void If the unit is altered by anyone other than Master Water Co...