60
UNDER VOLT
UNDER VOLT ENABLE
UNDER VOLT START
OVER FREQ
OVER FREQ ENABLE
Enter the option 1 to enable or disable the function that the
power of inverter derates when voltage is too low.
Enter the option 2 to adjust the exact value of the voltage
when power start to derate.
Interface
Description
-UNDER VOLT-
1: ENABLE
2: VOLT
Enable or disable the function that the power of inverter
derates when voltage is too low.
Interface
Description
-UNDER VOLT-
1: DISABLE
2: ENABLE
Press UP/DOWN to adjust the input figure.
Press Enter to confirm the input.
Interface
Description
-UNDER START-
INPUT:
200V
Enter the option 1 to enable or disable the function that the
power of inverter derates when frequency is too high.
Enter the option 2 to adjust the exact value of the frequency
when power start to derate.
Interface
Description
-OVER FREQ-
1: ENABLE
2: FREQ
Derate power when Frequency over.
The default option is enable.
Interface
Description
-OVER FREQ-
1: DISABLE
2: ENABLE
User Manual
61
OVER FREQ START
UNDER FREQ
UNDER FREQ ENABLE
UNDER FREQ START
REACT RESP
Press UP/DOWN to adjust the input figure.
Press Enter to confirm the input.
Interface
Description
-OVER START-
INPUT:
50.50Hz
Enter the option 1 to enable or disable the function that the
power of inverter derates when frequency is too low.
Enter the option 2 to adjust the exact value of the frequency
when power start to derate.
Interface
Description
-UNDER FREQ-
1: DISABLE
2: FREQ
Derate power when Frequency is too low.
The default option is enable.
Interface
Description
-UNDER FREQ-
1: DISABLE
2: ENABLE
The function that the power of inverter derates when
frequency is too low.
Press UP/DOWN to adjust the exact value of the frequency
when power start to derate.
Interface
Description
-UNDER FREQ START-
INPUT:
50.50Hz
The input value of Reactive response time.
The value ranges from 6s to 60s and default value is 10s.
Interface
Description
-REACT RESP-
INPUT:
10s
Value range
(6s ~ 60s)