27
CV - Table -
Standard settings of the 8FS-decoder. (D = Default, A = analog operation)
Table of configuration variables (CV table)
CV Description
D A
Range Note
1 Loco address (standard short)
3
1...127 if CV 29 bit 5 = 0
2 Starting voltage
2
1...255 CV 2 x (1/255 track voltage)
3 Acceleration time
3 √
1...255 CV 3 x 2ms x (1/255 track v.)
4 Braking time
10 √
1...255 CV 4 x 2ms x (1/255 track v.)
5 Top speed
200 √
1...255 CV 5 x (1/255 track voltage)
6 Mid speed
50
1...255 CV 6 x (1/255 track voltage)
7 Software version
---
---
read only
8 Manufacturer ID
123
---
read only
8 Decoder reset functions (refer to Attachment 5)
(6 ranges available)
11
16
22
33
44
66
basic settings
Programming lock
LF/LR and FA1...FA2
FA3...FA6
FA7...FA10
Motor settings
11 Waiting time f. analog mode detection 30 √ 30...255 1ms per value
13
Function outputs in analog mode
(On if value set)
15 √ 0... 255
Add the values to the desired
functions!
A1 = 1, A2 = 2, A3 = 4,
A4 = 8, A5 = 16, A6 = 32,
A7 = 64, A8 = 128
15
16
Programming lock (CV 15: Key / CV 16: Lock)
Standard Values see CV 255
0...255 active if CV 15 ≠ CV 16
17 Long loco address (High Byte)
128
128...
10239
Only active
if CV 29 bit 5 = 1
18 Long loco address (Low Byte)
19 Multiple Unit Address
0
1...99