POSITIONING THE HEATER
Select a dry site on any rigid flooring surface, keeping in mind the following:-
• A central position free of strong draughts will ensure even heat dispersal.
• Check that the flue and its shielding will be able to pass through the ceiling space and roof
without interfering with any structural timberwork.
• The flue must terminate above the roof no less than 500mm clear of any part of the roof, and at
least 1 metre horizontally from any neighbouring structure.
• The minimum specified clearance distances to heat sensitive materials MUST be maintained at all
times, and sufficient room will be needed to facilitate servicing the heater.
• Avoid positions where curtains or furniture might accidentally come too close to the heater.
• Select a location where the gas supply can be installed readily. A power outlet will be required.
INSTALLING PROCEDURE
SHIMS
(Cardrona Models)
.
The glass panels are protected from shipping damage by paper shims
fitted between the front and side glasses. Before lighting the heater, remove the shims after removing
the dress guard, if fitted.
GAS.
Access to the gas connection point is obtained by removing the cover panel on the rear of the
cabinet. Remove the two screws and lift the panel up and out.
Connection is made to the STD models using a 3/8” BSP fitting. The ACC and ECS models use a 1/2”
BSP fitting. In all cases a shut-off valve should be installed directly behind the heater to facilitate
isolation of the heater for servicing.
It is essential to purge all gas lines before making the connection to the heater to eliminate any swarf.
THERMOSTATS
STD Models. A thermostat cannot be fitted.
ACC Models. Two accessory options are available:
• The hand-held IRRC Model 300 non-programmable remote thermostat.
• The wall-mounted programmable thermostat.
Instructions for installing both options are supplied with them.
ECS Models. An optional battery powered wall-mounted programmable thermostat is available.
GAS VALVES