![Masimo Rad-8 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/masimo/rad-8/rad-8_operators-manual_1735234010.webp)
Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual
2-5
s y s t e m d e s c r i p t i o n
2-4
Rad-8 Signal Extraction Pulse Oximeter Operator’s Manual
2
R a d - 8 r e a r p a n e l
1
NURSE CALL
CONNECTOR
Use the 1/4” round Connector to interface with a nurse call
system. This is a mono output and should be utilized with a
mono cable. All external device connections to the Nurse
Call Connector must be IEC-60950 compliant.
2
SERIAL OUTPUT
CONNECTOR
Use the Serial Output Connector to connect a serial device,
including a serial printer, RadNet Interface Module, RadLink
Interface Module or PC, to the Rad-8. See Section 7,
Serial
Interface Specifications
. All external device connections to
the Serial Output Connector must be IEC-60950 compliant.
3
POWER ENTRY
MODULE
The power entry module contains the input connector for
AC power. The AC input provides power to the system from
the AC line. Always connect the pulse oximeter to the main
power for continuous operation and/or battery recharging.
4
EQUIPOTENTIAL
GROUND CONNECTOR
Use the Equipotential Ground Connector for grounding.
s y s t e m d e s c r i p t i o n
2
SYMBOLS
The following symbols are found on the back of the Rad-8 pulse oximeter or packaging and
are defined below:
SYMBOLS
RS-232
Equipotential Ground Terminal
Caution, consult accompanying documents
Nurse Call Interface
WEEE compliant
Defibrillation Proof (see front panel)
Mark of Conformity to European Medical Device Directive
93/42/EEC
Rx Only
Federal law restricts this device to sale by or on the order
of a physician (USA audiences only)
Year of manufacture
Underwriter's Laboratories Inc. approved
5%-95% RH
Storage humidity range: 5% to 95%
-40 C
+70 C
+1060 hPa - +500 hPa
795 mmHg - 375 mmHg
Storage temperature range: +70˚C to -40˚C
Storage altitude range: +1600hPa to +500hPa
Keep dry
Fragile/breakable, handle with care
P2
P1
RS-232
MEDICAL ELECTRICAL EQUIPMENT
UL 60601-1/CAN/CSA C22.2 No. 601.1
80FK
100-240v~50-60 Hz 15VA MAX
100-240v~50-60 Hz 15VA MAX
Made in USA
Manufactured by:
Masimo Corporation
Irvine, CA 92618
USA
Rx Only
Covered by one or more of the following U.S. Patents: RE38,492, RE38,476,
6,850,787, 6,826,419, 6,816,741, 6,699,194, 6,684,090, 6,658,276, 6,654,624,
6,650,917, 6,643,530, 6,606,511, 6,501,975, 6,463,311, 6,430,525, 6,360,114,
6,263,222, 6,236,872, 6,229,856, 6,206,830, 6,157,850, 6,067,462, 6,011,986,
6,002,952, 5,919,134, 5,823,950, 5,769,785, 5,758,644, 5,685,299, 5,632,272,
5,490,505, 5,482,036, international equivalents, or one or more of the patents
referenced at www.masimo.com/patents. Other patents pending.
Distributed by:
Masimo Corporation
Irvine, CA 92618
USA
1
2
3
4