- 16
PD 50 YS
GB
GB
2.5 N
OISE
EMISSION
The values listed are emission levels and not necessarily
safe operating levels. Although there is a correlation between
emission and exposure levels, this cannot be reliably used
to establish whether or not further precautions are required.
Among the factors which affect the effective level of exposure
of the workforce are the characteristics of the workplace,
other sources of noise, such as the number of machines
and other adjacent processes, and the time an operator is
exposed to the noise. Moreover, the permitted exposure
levels may vary from country to country. Nonetheless, this
information allows the machine user to better evaluate the
danger and risk.
Guaranteed acoustic power level L
WA
96
dB(A)
Acoustic pressure level at the operator
station L
pA
83
dB(A)
in accordance with Directive 98/37/EC
The measurements were made with the generator running and in accordance with Directive 98/37/EC.
in accordance with Directive 2000/14/EC
The measurements were made with the generator running and in accordance with Directive 2000/14/EC, and regarding the place of testing, the
measuring conditions and the instruments in accordance with ISO 3744 of 1995. Measurement uncertainty values: +1dB.
MODEL
PD 50 YS