background image

VOYAGER 6020

      

- 6

GB

GB

PRELIMINARY PRESCRIPTIONS

CAMPO D’IMPIEGO:

THE GENERATOR GROUP IS PROPER FOR TO PRODUCE IN WAY AUTONOMOUS ELECTRIC ENERGY IN
THE LIMITS OF TENSION AND WATT DECLARED BY THE BUILDER

To consult attentively this manual before proceeding to the use to any intervention on the car.

FAILURE TO RESPECT THE SPECIFICATIONS CONTAINED IN THIS USE AND MAINTENANCE MANUAL

WILL RESULT IN FORFEITURE OF THE GUARANTEE ON THE PRODUCT.

This manual was drawn up by the manufacturer and forms an integral part of the generator equipment, definition used
as indicated in Directive 89/392 EEC; the information contained in the manual is addressed to all the persons involved
in the operating life cycle of the generator, and is necessary to inform both those who effectively carry out the different
operations and those who coordinate the activities, to arrange the necessary logistics and to regulate access to the
place where the generator will be installed and operated.

This manual was drawn up by the manufacturer with the purpose of providing essential information and instructions
for proper use and maintenance in conditions of safety. It constitutes an integral part of the generator equipment and
must carefully be protected from any agent which may damage it for the entire life cycle of the generator. The manual
must accompany the generator if transferred to another user or owner.

The manual defines the purpose for which the generator was constructed and contains all the information necessary
to guarantee safe and proper use.
Constant observance of the instructions contained in this manual guarantees the safety of the operator, protection
against damage to persons or things, operating economy and a longer life of the generator.

The drawings are provided by way of example.   Even if the generator in your possession differs from the illustrations
contained in this manual in elements of little significance, for example the colour, the safety of the generator and
the information provided are nevertheless guaranteed.

To facilitate consultation, it has been divided into sections identifying the main concepts;  for a quick look at the
topics, consult the index.

Ongoing improvement and development of the product may have led to modifications to the generator which are not
included in this publication.

Whenever a problem concerning the generator or this publication arises, consult with Mase Generators SPA for the
latest information available.

Содержание Voyager 6020 Auto

Страница 1: ...mase mase mase mase maseGENERA TORS VOYAGER 6020 AUTO Rev 2 F M 28 06 2013 cod 43186 Tipo modello N matricola Codice MANUALE DI USO E MANUTENZIONE I USE AND MAINTENANCE MANUAL GB...

Страница 2: ...uppo elettrogeno che Lei ha acquistato il frutto di anni di esperienza nel settore e per la moderna conce zione il robusto dimensionamento i materiali impiegati i continui aggiornamenti costituisce un...

Страница 3: ...rtment The generator you have purchased is the fruit of years of experience in the sector and for the modern conception the strong sizing the materials employees the continuous updatings constitutes a...

Страница 4: ...uit connection 20 3 9 System bleeding 20 3 10 Electrical connection 21 3 11 Battery connection 21 3 12 Controlpanelconnection 21 3 13 Powerconnection 22 3 14 Earthing 22 4 USINGTHEGENERATOR 23 4 1 Man...

Страница 5: ...ically by differential effect Skilled person Apersonwithtechnicalknow howorsufficientexperiencetoallowhimtoavoidthedangersinherentinelectricity mase specialised personnel A person able to evaluate the...

Страница 6: ...n Indicatesthatparticularattentionmustbepaidinordertopreventseriousriskswhichcould lead to death or possible harm to the health of personnel Aconditionwhichmayoccurduringthelifetimeofaproduct systemor...

Страница 7: ...safety Itconstitutesanintegralpartofthegeneratorequipmentand mustcarefullybeprotectedfromanyagentwhichmaydamageitfortheentirelifecycleofthegenerator Themanual must accompany the generator if transferr...

Страница 8: ...chnicians or personnel trained by mase have the necessary knowledge of the generator and the special equipment as well as the experience to carry out any operation in the most economical and reliable...

Страница 9: ...VOYAGER 6020 8 GB GB cod 42348 cod 42118 Cod 42655 cod 41781 Cod 41779 Cod 42349 Cod 41777 Cod 41775 Cod 42108 cod 41781 Cod 42346 Cod 42653 Cod 42861 1 3 Symbols on the generator group...

Страница 10: ...dMaintenanceManualbeforestartingthegenerator The mase SpA has been designed so as to guarantee safe and reliable operation provided that the instructions are followed Otherwise personal injury or dama...

Страница 11: ...s been restored the generator may explode burn or cause fires in the electrical system of the facility No smoking or use of open flames Do not clean lubricate repair or adjust moving parts Do not exti...

Страница 12: ...ns or things deriving from inobservance of the safetyregulations Carefully examine the safety warning plates on the generator and respect the relevant instructions 1 5 1 Danger of entanglement Do not...

Страница 13: ...that fuel does not overflow from the engine tank respecting the maximum level In the event of fuel spillage from the tank thoroughly dry and clean the parts involved Check that there are no fuel leaks...

Страница 14: ...hArticles313and318ofPresidentialDecreeNo 54727 04 55 aswellasChap 11SectionIV oftheCEI64 8regulation Immediatelychangewetoveralls Insulate all the connectors and detached wires Donotleavethepowertermi...

Страница 15: ...ththefollowingapplicableregulationsand directives 98 37 ECandsubsequentamendments Essential machine requirements for safety and health protection Machine directive 73 23 ECandsubsequentamendmentsconta...

Страница 16: ...or a boundless number of hours for year among the interval of maintenance prescribed by the builder and under the environment conditions established by the norm ISO 3046 1 The middle power during a pe...

Страница 17: ...components 1 Base chassis 2 Openable cowling engine side 3 Supportfoot 4 Controlpanel 5 Lock with key 6 Engine 7 Alternator 2 9 Instrument and control panel See Fig 2 Each generator is fitted with an...

Страница 18: ...ected to a control panel thatcanbeinstalledinthemotorvehicle whichcontrols thestarting stoppingfunctionsandthesafetyprotections 3 2 Ventilation Voyager 6020 generator is equipped with an internal forc...

Страница 19: ...haustinthelowerpartofthegenerator Fig 9 an OPTIONAL manifold can be supplied which isturneddownwards Thisreplacesthestandardmanifold Onthebottomofthecasingaretheholesforsecuringthe exhaust using the b...

Страница 20: ...vehicle itself Thegeneratorisfittedwithasuction compression pump SC able to pump fuel up to a maximum height of 50 cm Fig 12 and with a cartridge filter It is best to equipthegenerator tankconnectionw...

Страница 21: ...vingthe numberofratedrevs Aircanpenetrateinsidethefeedcircuitthroughafaulty seal joint pipes filters tanks or when fuel inside the tank is at minimum level To eliminate the air inside the feed circuit...

Страница 22: ...in sequence Connect the negative pole of the battery to the terminal marked ref 1 Connect the positive pole of the battery to the terminal marked ref 1 Covertheconnectionswithspecialpetroleumgrease to...

Страница 23: ...odifiedtoavoidfaulty operationofthecontrolpanelelectroniccomponents 3 13 Power connection The power cables must be connected directly to the thermal switch as shown on ref 1 Cables must pass through t...

Страница 24: ...e more than 5 consecutive starting attempts as you may damage the starter motor During the running in period the first 50 hours do not apply loads exceeding 70 of the rated power of the generator For...

Страница 25: ...n c START SetautomaticmodepressingAUTOpushbutton ref 2 Icon appears on display if no alarm are present AUTO mode will allow the generator to operate fully automatic starting and stopping the generato...

Страница 26: ...Any maintenance operation on the generator must be carried out with the engine off after leaving it to cool down sufficiently Carefully read paragraph 1 5 General danger information in the manual Peri...

Страница 27: ...ollection centres for disposal Wear gloves to protect the hands from contact with oil In case of accidental contact with engine oil thoroughly wash the affected part with soap and water Do not top up...

Страница 28: ...E LINE FUEL FILTER Follow the instructions given in the manual of the type of fuel filter installed ref 3 See Chap 3 6 1 Fuel filter 6 8 BLEEDING THE FUEL SYSTEM The generator is equipped with an auto...

Страница 29: ...angeontheexpansion tank ref 3 If the coolant level is down top up having care to not overfilling the cup Don t remove the cover radiator ref 3 4 when the engine is hot to avoid dangerous spillagesofco...

Страница 30: ...ed with Vaseline to prevent corrosion and the formation of oxide If necessary top up with distilled water Ifthebatteryisleftcompletelyflatforlongperiodsof time there is a risk of irreparably damaging...

Страница 31: ...Check the correct air flow inside canopy and coolant flow inside cooling system Replace all fuel pipes and cooling pipes or every 2 years Intake Exhaust system Check the air cleaner element Replace ai...

Страница 32: ...rswitchesoffduringthe operatingperiod Check if a protection has been activated Solve the problem and restart Check if there is fuel in the tank Fill up Thereishighsmokeemissionfromtheexhaust Check tha...

Страница 33: ...d in the picture Check that the hoisting cables or chains are homologated or of sufficient capacity and also check the minimum cable length Calculate the cable capacityconsideringthatforeachofthetwosl...

Страница 34: ...rding to mase instructions The service procedures are carried out exclusively by mase specialised technical personnel The electrical system and the loads to which the generator is connected is in conf...

Страница 35: ...48502 3 2 1 ATO FUNCTION NC START NO STOP EMERGENCY STOP 6 4 3 5 2 1 Hz 60 Hz 50 0 N L1 USCITA UTILIZZO POWER OUTPUT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 4 3 6 2 5 11 WIRING DIAGRAM 11 1 WIRING...

Страница 36: ...0 Arming 0 308 RESERVED 309 Digital input 2 source 0 Input source 10 310 Digital input 2 polarity 0 Polarity 311 Digital input 2 action if source user config 0 Action 312 Digital input 2 arming if so...

Страница 37: ...09 Return Delay 0 00 1 510 Cooling Time 0 00 1 511 ETS Solenoid Hold 0 00 0 512 RESERVED 513 RESERVED 514 RESERVED 515 Breaker trip pulse 0 00 0 516 Breaker close pulse 0 00 0 CONFIGURATION PARAMETERS...

Страница 38: ...4 RESERVED 725 Charge alt failure enable On 1 Off 0 1 726 Charge alt failure trip 00 0 V 7 4 CONFIGURATION PARAMETERS ALTERNATIVE CONFIGURATION 801 Alt config Enable configuration On 1 Off 0 0 802 Alt...