Page 33
mPower 300 Series (Rev G)
5.4.5 Display modes for actual and set values
In general, the display panel shows the actual output voltage and the related set value in the left half of the display, and
the actual output current and related set value in the right half. In order to have the power set value in direct access, the
display mode can be switched.
Mode
UI
Only voltage (U) and current (I) are displayed. This is the default mode.
The set value of power is then only accessible in the setup menu or
when switching to a different view mode with the arrow buttons
or
.
Mode
UP
Alternatively to the actual and set values of current (I) and voltage (U)
the actual and set values of power (P) are displayed.
The set value of current is then only accessible in the setup menu or
when switching to a different view mode with the arrow buttons
or
.
►
How to change the display mode in the menu
1. Switch off the DC output and push button
to call the setup menu.
2. In the menu navigate to
HMI Setup
and push
. Then in the submenu navigate to
Page Setup
and push
again.
3. Select the desired display mode (see above) with the right-hand rotary knob.
4. Accept the settings with
or discard them with
.
►
How to change the display mode directly
During normal display (as shown in the figures above), push any of the arrow buttons
to switch be-
tween the view modes.
Depending on your setting, the main display will change after leaving the setup menu and the right-hand rotary knob is
then either assigned to set value of current or power