6
S y n c h ro Z a p QX 2 5 0
W A R N I N G !
Disconnect the fixture from AC power before proceeding.
The lamp operates under high temperature and pressure
and can explode when hot. Always allow a hot lamp to cool
for at least 5 minutes before removing it from the fixture
and wear safety goggles to protect your eyes.
1.
Remove the 2 lamp access screws from the lamp
assembly and gently remove the assembly. See
Figure 1.
2.
Remove the old lamp, if any, by its ceramic base.
3.
Holding the new lamp by its ceramic base (do
not touch the glass), align the pins as shown in
Figure 2 so that the small pin goes in the small
hole. Insert the lamp firmly and squarely into the
socket and ensure that all 4 small projections on
the ceramic base touch the face of the socket.
4.
Clean the glass bulb with the cloth supplied with
the lamp, particularly if your fingers touch the
glass. A clean, lint-free cloth wetted with alcohol
may also be used.
5.
Turn the lamp assembly so the wires are at the top.
Gently insert the assembly, making sure the lamp
fits through the opening in the reflector. Replace
the lamp access screws.
6.
The lamp holder is pre-adjusted at the factory; however, precise align-
ment to compensate for slight variations between lamps may improve
performance. See “Adjusting the lamp” on page 14.
P o w e r i n g t h e f i x t u r e
W A R N I N G !
The fixture must be grounded (earthed).
The voltage and frequency settings must match the local
AC power supply.
Figure 2