background image

   User Manual                                                                             3

 

 s e c t i o n 1

 

INTRODUCTION

 

Thank  you  for  selecting  the  MAC  600  from  Martin.  This  intelligent  moving-head  Fresnel  color  changer  is  fast,  quiet,  and 

reliable. It delivers exceptionally bright light that instantly snaps or smoothly  fades to virtually  any color, at any intensity, 
anywhere on stage. 

 

About this manual 

This manual covers the MAC 600 with magnetic ballast and the MAC 600 Ewith electronic ballast. “MAC 600/E” is used to 

refer to both models when describing common features or procedures. 

 

This manual describes the features of software version 2.3. The latest MAC 600/E software and documentation are available 

from the Service and Support area of the Martin web site at http://www.martin.dk.

 

Safety precautions 

 

This product is for professional use only. It is not for household use.

 

 

This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, 

and  falls.  5HDGWKLVPDQXDO  before  powering  or  installing  the  fixture,  follow  the  safety  precautions  listed  below  and 
observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, 
please contact your Martin dealer or call the Martin 24-hour service hotline at +45 70 200 201.

 

To protect yourself and others from electric shock  

 

Disconnect the fixture from AC power before removing or installing the lamp, fuses, or any part, and when not in use. 

 

 

Always ground (earth) the fixture electrically. 

 

 

Use  only  a  source  of  AC  power  that  complies  with  local  building  and  electrical  codes  and  has  both  overload  and 
groundfault protection. 

 

 

Do not expose the fixture to rain or moisture. 

 

 

Refer any service operation not described in this manual to a qualified technician.

 

To protect yourself and others from UV radiation and lamp explosion 

 

Never operate the fixture with missing or damaged lenses and/or covers.  

 

 

When replacing the lamp, allow the fixture to cool for at least 15 minutes before opening the fixture or removing the 
lamp. Protect your hands and eyes with gloves and safety glasses. 

 

 

Do not stare directly into the light. Never look at an exposed lamp while it is lit. 

 

 

Replace the lamp before usage exceeds the maximum service life, or if the lamp is defective or worn out. 

 

To protect yourself and others from burns and fire 

 

Never bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the specified type and rating.

 

 

Keep all combustible materials (for example fabric, wood, paper) at least 1.0 meter (39 inches) away from the fixture. 
Keep flammable materials well away from the fixture.

 

 

Do not illuminate surfaces within 1.0 meter (39 inches) of the fixture.

 

 

Provide a minimum clearance of 0.1 meters (4 inches) around fans and air vents. 

 

 

Never place filters or other materials over the lens. 

 

 

Allow the fixture to cool for at least 5 minutes before handling. 

 

 

Do not modify the fixture or install other than genuine Martin parts. 

 

 

Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F). 

 

To protect yourself and others from injury due to falls 

 

When suspending the fixture, verify that the structure can hold at least 10 times the weight of all installed devices.

 

Содержание MAC 600

Страница 1: ...ual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000018 Rev G section 1 INTRODUCTION About this manual 4 Sa...

Страница 2: ...Manual control 13 Test sequences 14 Utilities 14 section 1 MAINTENANCE AND BASIC SERVICE OPERATIONS 14 Removing the printed circuit board 14 Replacing the printed circuit board 14 Replacing fuses 14 C...

Страница 3: ...source of AC power that complies with local building and electrical codes and has both overload and groundfault protection Do not expose the fixture to rain or moisture Refer any service operation no...

Страница 4: ...th the Philips MSR 575 2 and MSD 575 and the Osram HSR 575 2 QVWDOOLQJDQ RWKHUODPSPD GDPDJHWKHIL WXUHThe lamp holder is pre adjusted at the factory precise alignment may be necessary due to slight var...

Страница 5: ...ot clearly identified or if you have any doubts about proper installation consult a qualified electrician Wire Color Pin Symbol Screw US brown live L yellow or brass blue neutral N silver yellow green...

Страница 6: ...te the link by installing a termination plug in the output socket of the last fixture on the link The termination plug which is simply a male XLR connector with a 120 ohm 0 25 watt resistor soldered b...

Страница 7: ...to disable pan and tilt reset This is handy if you want to change settings while the MAC 600 E is in a flight case As the fixture does not run through the entire reset procedure error messages will be...

Страница 8: ...rrides of the pan tilt speed PTSP shortcut SCUT and studio mode MOdE menu settings In vector mode the controller fade time should be set to 0 i e the position bumps from one value to the next However...

Страница 9: ...h directions at different speeds The Shortcuts SPEC SCUT setting determines whether the wheel takes the shortest path to the next position or turns in one direction only The setting may be overridden...

Страница 10: ...and any error messages are displayed when the MAC 600 E is turned on To enter the menu press MENU Use the and keys to move within the menu To select a function or submenu press ENTER To escape a funct...

Страница 11: ...if pan tilt is not smooth Effects speed EFSP FAST Normal full speed operation SAFE Reduced speed operation mainly for early models Display on off SPEC dISP ON Display stays on OFF Display goes out 2 m...

Страница 12: ...start code is 0 and that the fixture is receiving the expected commands If the fixture is set to a DMX mode where some or all of the channels between 10 and 13 are not used the readout on these chann...

Страница 13: ...c u i t b o a r d t e s t SPEC PCBT 3 tests of the circuit board for service use F a c t o r y t e s t SPEC FTST An effects test WTST a movement test MTST and a sensor test STST used for factory qual...

Страница 14: ...uit board To unplug a connector hold the plastic connector never pull the wires and pull it straight off the pins 4 Grasp the black pins on either end of the circuit board and gently pull it out You m...

Страница 15: ...eaning and servicing components in the head is best left to qualified Martin technicians To access the optical components remove the head cover Remember to attach the internal safety cable when reasse...

Страница 16: ...ating fixture damage and or poor performance MAC 600 magnetic ballast 1 Disconnect the MAC 600 from AC power Remove the top covers 2 Find the correct transformer and ballast terminals for your AC supp...

Страница 17: ...l o a d If the data is corrupted during transmission a check sum error CSER will occur and after 15 seconds the fixture will automatically switch over to boot mode UPLd and be ready for a boot mode u...

Страница 18: ...h SPEC dRES set to OFF and cyan magenta and yellow set between 230 and 232 0 19 20 49 50 112 113 115 116 122 123 127 128 147 148 167 168 187 188 207 208 217 218 227 228 237 238 247 248 255 0 7 8 19 20...

Страница 19: ...dom color medium Random color slow 7 0 1 255 0 0 100 HDP6KDSHU Open Beam shaper left right 8 0 2 3 170 171 255 0 1 1 67 67 100 HDP6KDSHU Open Beam shaper left right Frost 9 0 255 0 100 3DQ RDUVHELW06...

Страница 20: ...7 98 98 99 100 6SHHG LPPHU 0 P6KDSHU Tracking Fast slow Tracking MOdE NORM studio mode off Tracking MOdE STUd studio mode on Tracking SCUT OFF shortcuts off Tracking SCUT ON shortcuts on Fast Speed Co...

Страница 21: ...ut no Lamp ON command has been received This can occur if the lamp relays are stuck in the ON position or if the lamp power feedback circuit has failed You can still operate the fixture but may not be...

Страница 22: ...ion Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 termination plug Insert termination plug in output jack of the last fixtu...

Страница 23: ...nd frequency Disconnect fixture Check ballast and transformer settings and correct if necessary MAC 600 E Incorrect ballast type selected Check S N and set ballast type personality accordingly Misalig...

Страница 24: ...i c a l m a g n e t i c b a l l a s t v e r s i o n Ballast taps 200 230 245 V 50 Hz 208 27 V 60 Hz Power and current 750W 3 9A 230V 50Hz 750W 4 2A 208V 60Hz Power factor PF 0 85 E l e c t r i c a l e...

Страница 25: ...flux 21 500 lm Center intensity w standard 25 lens hood 291 000 candela Center intensity w optional 18 long lens hood 722 000 candela Center intensity w optional 65 diffuser 34 500 candela T h e r m...

Страница 26: ......

Страница 27: ...Start code 0 MAC 600 DMX Protocol Implemented from CPU software version 2 0...

Страница 28: ...T tracking mode 0 2 246 251 S normal PTSP or shortcuts off 246 248 F fast PTSP or shortcuts on 249 251 blackout speed 252 255 variable speed points to fast...

Отзывы: