User Manual 25
•
Fuse F601 ................................................................................................................... T 5.0 A, 250 V
•
Fuse F602 .................................................................................................................... T 4.0 A, 250 V
•
Fuse F603 ................................................................................................................ T 0.315 A, 250 V
C o m m u n i c a t i o n
•
Protocols ................................................................................USITT DMX512 (1990) / Martin RS-485
•
DMX start code ................................................................................................................................. 0
•
Recommended cable......................... 24 AWG (min.), low capacitance, 85-150
Ω
shielded twisted pair • Connector
type....................................................................... 3-pin XLR male/female (pin 1 = screen)
C o m p a t i b l e l a m p s
•
Osram HSR-575/2..........................................575 W, 85 lm/W, 1000 h avg. life, 6000K, P/N 97010200
•
Philips MSR-575/2 .........................................575 W, 85 lm/W, 1000 h avg. life, 7200K, P/N 97010201
•
Philips MSD-575 ............................................575 W, 75 lm/W, 2000 h avg. life, 6000K, P/N 97010202
P h o t o m e t r i c
•
Total integrated luminous flux ...............................................................................................21,500 lm
•
Center intensity w/ standard 25° lens hood ................................................................ 291,000 candela
•
Center intensity w/ optional 18° long lens hood.......................................................... 722,000 candela
•
Center intensity w/ optional 65° diffuser....................................................................... 34,500 candela
T h e r m a l
•
Maximum ambient temperature..................................................................................... 40° C (104° F)
•
Maximum surface temperature under normal conditions...............................................140° C (284° F)
A c c e s s o r i e s
•
2 unit flight case...................................................................................................................91510002
•
18° “long front” with lens.......................................................................................................91610005
•
65° floodlight diffuser on standard front ................................................................................91610008
•
90 x 90 mm color/diffuser filter holder kit ..............................................................................91611001
•
Termination plug, 3-pin XLR male, 120 Ohm .........................................................................91613017
•
G-clamp ...............................................................................................................................91602003
•
Half-coupler clamp ...............................................................................................................91602005
•
Clamp adaptor with 1/4-turn fasteners ..................................................................................91602001
•
Outdoor Protection Dome .....................................................................................................90525010
•
MPBB1 Uploader..................................................................................................................90758410
•
MP2 Uploader: .....................................................................................................................90758420
•
4 Channel Opto-Isolated RS-485 Splitter/Amplifier................................................................90758060
Содержание MAC 600
Страница 26: ......
Страница 27: ...Start code 0 MAC 600 DMX Protocol Implemented from CPU software version 2 0...