User Manual 17
3.
Verify that the primary fuse, which is located near the power switch, is correct for the voltage setting. Use a T 6.3 A fuse
when the transformer is set at 200, 210, 220, 230, or 240 V. Use a T 10 A fuse when it is set at 100, 110, or 120 V.
Updating software
The latest MAC 600/E software is available from your Martin dealer and the Martin Professional web site. Be sure to read the upgrade
notes included with the software.
Software updates are installed using a Martin MPBB1, MP-2, or a LightJockey 4064 DMX interface card. The procedure is found in
the upload device’s user manual and, when using the 4064 card, the Martin Software Uploader program’s online help file.
N o r m a l u p l o a d
The uploader is connected to the fixture just like a controller. Under normal conditions, software can be installed from a remote location
- there is no need to set the MAC 600/E to boot mode. Please refer to the uploader manual for instructions.
B o o t m o d e u p l o a d
If the data is corrupted during transmission a check-sum error (
CSER
) will occur and after 15 seconds the fixture will automatically
switch over to boot mode (
UPLd
) and be ready for a boot mode upload.
If a software upload to the MAC 600/E is interrupted, the fixture must be powered off for at least 10 seconds before a new upload can
be attempted. When powered on, a check-sum error will occur and it will automatically go into boot mode, ready for a second upload
attempt. Select boot mode upload on the upload device.
If there is no functional software in the MAC 600/E memory, the fixture must be set to boot mode manually before starting the upload.
If the control panel works, select
UPLd
from the
SPEC
menu and confirm when
SURE
is displayed by pressing [ENTER].
If the control panel does not work, boot mode can be engaged by moving jumper PL121 on the main circuit board to pins 1 and 2
as follows.
1.
Remove the printed circuit board as described above. It
2.
may not be necessary to unplug the connectors.
Position jumper PL121 to boot mode (INIT) as shown
above. See also the circuit board layout diagram on page
24.
1
boot setting
1
normal
setting
PL121
PL121
Содержание MAC 600
Страница 26: ......
Страница 27: ...Start code 0 MAC 600 DMX Protocol Implemented from CPU software version 2 0...