18
DMX control
Channel 1
DMX value
range
Function
Macro description
Default
value
Haze
output
Level
0-19
Idle range
None
0
20-29
Haze 5%
30-39
Haze 10%
……..
…….
210 -255
Haze 100%
Channel 2
DMX value
range
Function
Macro description
Default
value
Fan output
level (fan
will always
run if haze
is active)
0-19
Idle range
None
0
20-29
Fan 5%
30-39
Fan 10%
……..
…….
210 -255
Fan 100%
Channel 3
DMX value
range
Function
Macro description
Default
value
Special
functions
0-50
Idle range
None
0
51-100
Prime
5 seconds within
range to activate
once
101-150
Auto Fan
mode
None (level
triggered)
151-200
Heater off &
shutdown
5 seconds within
range to activate
once
201-255
Heater on
(normal
operation)
None, but heaters
will stay on if
channel 3 returns to
zero
Note that when the heaters are on, Channel 3 can stay at level 0 without
affecting the operation of the machine.
This means that Channel 3 need only go to 100% once at the start of a show,
then it can assume a default of zero without the heaters turning off, thus ensuring
that the machine is ready when the show runs again. To turn the heaters off, use
the Heater Off macro.