Exterior 1200 Wash user manual
8.8 Troubleshooting
Problem
Probable cause(s)
Remedy
No response from
luminaire when power is
applied.
No power to luminaire.
Check power cables.
Main or low-voltage fuse
blown.
Replace fuse.
Secondary fuse(s) blown
(located on PCB).
Refer to Martin Architectural.
Luminaire resets when
power applied but does
not respond correctly to
DMX controller. LED 2
lights steady green.
Incorrect DMX addressing.
Check luminaire addressing on
controller. If no error found, check
luminaire’s DMX address setting.
Luminaire resets when
power applied but does
not respond correctly to
DMX controller. LED 2
does not light steady
green.
Bad data link connection.
Inspect cables and correct poor
connections and/or broken cables.
Data link not terminated.
Insert DMX termination resistor in data
output of last luminaire on each branch of
the data link.
Luminaire resets when
power applied but does
not respond correctly to
DMX controller. LEDs
flash red and green.
Defective luminaire.
Bypass luminaires on the data link one at
a time until normal operation is regained.
Electronic or mechanical
failure.
Refer to Martin Architectural.
Luminaire software corrupted.
Upload new software. If luminaire
repeatedly fails to reset correctly, refer to
Martin Architectural for boot mode
upload.
Luminaire cuts out
intermittently, especially
in hot weather.
Luminaire temperature too
high: thermal cutout shutting
down power to avoid
overheating.
Stop using luminaire. Inspect for dirt
buildup and clean if necessary.
If luminaire is clean or if problem
reoccurs, stop using luminaire and refer
to Martin Architectural.
No light output.
Lamp has been in use and is
too hot to restrike.
Allow to cool for 8 minutes before
attempting to restrike.
Lamp defective or worn out.
Replace lamp.
Lamp cutout inside front cover
not correctly deactivated.
Open front cover. Make sure that left-
hand slider lock presses cutout switch.
Power settings do not match
local AC voltage and
frequency.
Disconnect luminaire and open rear
cover. Check jumper lead settings and
correct if necessary.
Temperature or fans error
Check display for error message. Check
for dirt buildup. Check that ambient
temperature does not exceed maximum.
Refer to Martin Architectural.
Lamp life unexpectedly
short (note that 3000
hours is
average
life, not
minimum
).
Defective lamp.
Replace lamp.
Strain on lamp or excessive
lamp strikes.
Always allow lamp to fully warm up for
five minutes before turning off.
Leave lamp powered and use intensity
command to reduce light output to zero if
only cutting light output for short periods.
Leave power applied for at least 8
minutes after switching off lamp to allow
cooling fans to reduce temperature.
Содержание Exterior 1200 Wash
Страница 1: ...user manual Exterior 1200 Wash ...
Страница 3: ...3 Section 1 Safety ...
Страница 9: ...Section 2 Introduction ...
Страница 12: ...12 Exterior 1200 Wash user manual ...
Страница 13: ...Introduction to the Exterior 1200 Wash 13 Section 3 Installation ...
Страница 25: ...Installing a data link 25 Section 4 General ...
Страница 30: ...30 Exterior 1200 Wash user manual ...
Страница 31: ...General 31 Section 5 Settings and configuration ...
Страница 39: ...Luminaire settings 39 Section 6 Stand alone operation ...
Страница 49: ...Stand alone operation 49 Section 7 DMX control ...
Страница 54: ...54 Exterior 1200 Wash user manual ...
Страница 55: ...DMX controller operation 55 Section 8 Service and accessories ...
Страница 70: ...70 Exterior 1200 Wash user manual ...
Страница 71: ...Accessories 71 Section 9 Reference ...
Страница 82: ...Notes ...
Страница 83: ......
Страница 84: ...www martin architectural com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...