5. Tighten the cable gland as described in ”Installing a cable in a cable
6. If you are not continuing the data link from the PSU to another PSU,
see Figure 13:
• Install the supplied DMX terminator in the unused
DMX OUT
terminals so that it bridges the
DMX+
and
DMX+
terminals.
• Install a blanking plug in the unused cable gland marked
DMX Line
2 (
see ”Installing a blanking plug in an unused cable gland” on page
24).
7. If you are continuing the DMX data link to another PSU, follow the
instructions in the next section.
Figure 13: DMX termination in last PSU on link
DMX termination
Install DMX terminator
across DMX +ve and DMX -ve
Install plugs in all unused
cable glands