Specifications
79
Exterior 100 Luminaire
Calibrated RGB mode, RGBW Luminaire . . . . . . . . . . . . 12 W, 0.4 A at 30 VDC
Uncalibrated RGBW mode, RGBW Luminaire . . . . . . . . . 18 W, 0.6 A at 30 VDC
Calibrated mode, white (CW, NW or WW) Luminaire . . . 17 W, 0.6 A at 30 VDC
Uncalibrated mode, white (CW, NW or WW) Luminaire. . 18 W, 0.6 A at 30 VDC
Measurements made at nominal voltage with all LEDs at full intensity. Allow for a
deviation of +/- 10%.
Thermal
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convection
Maximum ambient temperature (
Ta max.
), except
US model PSU for use in North America . . . . . . . . . . . . . . . 45° C (113° F)
Maximum ambient temperature (
Ta max.
), US model
PSU for use in North America . . . . . . . . . . . . . . . . . . . . . . . 40° C (104° F)
Minimum ambient temperature (
Ta min.
) . . . . . . . . . . . . . . . . . . . .
40° C (
40° F)
Approvals
EU safety . . . . . . . . . . .EN 60598-1, EN 60598-2-1
EU EMC . . . . . . . . . . . . .EN 55103-1, EN 55103-2,
. . . . . . . . . . . . . . . EN 61000-3-2, EN 61000-3-3
US safety (applies to system with
US model PSU). . . . . . . UL 1310, 1598, UL 8750
Included Items
Included with Luminaire
3 m (9.8 ft.) luminaire hybrid cable (pre-installed)
Adjustable mounting bracket
Included with Splitter
Blanking plug for sealing unused luminaire cable gland
Blanking plug for sealing unused hybrid cable gland
DMX line terminators
Included with PSU
Blanking plug for sealing unused data cable gland
Two blanking plugs for sealing unused mains power or hybrid cable glands
DMX line terminators
User manual
Accessories
Exterior 50 & 100 Infrared Remote Control Unit. . . . . . . . . . . . . . . P/N 90510210
Exterior 50 light shield, narrow . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510270
Exterior 50 light shield, medium . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510280
Exterior 50 light shield, wide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510290
Exterior 100 light shield, narrow . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510240
Exterior 100 light shield, medium . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510250
Exterior 100 light shield, wide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 90510260
Exterior 50 & 100 standard mounting post . . . . . . . . . . . . . . . . . . . P/N 90510310
Exterior 50 & 100 telescopic mounting post . . . . . . . . . . . . . . . . . . P/N 90510300