Martin Professional Wizard Extreme Скачать руководство пользователя страница 25

DMX operation

25

2. Look up the DIP-switch setting using the Martin DIP Switch Calculator 

at http://www.martin.dk/service/dipswitchpopup.htm or look for the 
address in the DIP-switch settings table below. 

3. Disconnect the fixture from power.
4. Set pins 1 through 9 to the ON (1) or OFF (0) position as listed in the 

table. 

Find the address in the following table. Read the settings for pins 1 - 5 to
the left and read the settings for pins 6 - 9 above the address. “0” means
OFF and “1” means ON. Pin 10 is always OFF for DMX operation. 

DIP-Switch Setting

0 = OFF

1 = ON

#9

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

#8

0

0

0

0

1

1

1

1

0

0

0

0

1

1

1

1

#7

0

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

#6

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

#1 #2 #3 #4 #5

0

0

0

0

0

32 64 96 128 160 192 224 256 288 320 352 384 416 448 480

1

0

0

0

0

1

33 65 97 129 161 193 225 257 289 321 353 385 417 449 481

0

1

0

0

0

2

34 66 98 130 162 194 226 258 290 322 354 386 418 450 482

1

1

0

0

0

3

35 67 99 131 163 195 227 259 291 323 355 387 419 451 483

0

0

1

0

0

4

36 68 100 132 164 196 228 260 292 324 356 388 420 452 484

1

0

1

0

0

5

37 69 101 133 165 197 229 261 293 325 357 389 421 453 485

0

1

1

0

0

6

38 70 102 134 166 198 230 262 294 326 358 390 422 454 486

1

1

1

0

0

7

39 71 103 135 167 199 231 263 295 327 359 391 423 455 487

0

0

0

1

0

8

40 72 104 136 168 200 232 264 296 328 360 392 424 456 488

1

0

0

1

0

9

41 73 105 137 169 201 233 265 297 329 361 393 425 457 489

0

1

0

1

0

10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490

1

1

0

1

0

11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491

0

0

1

1

0

12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492

1

0

1

1

0

13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493

0

1

1

1

0

14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494

1

1

1

1

0

15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495

0

0

0

0

1

16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496

1

0

0

0

1

17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497

0

1

0

0

1

18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498

1

1

0

0

1

19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499

0

0

1

0

1

20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500

1

0

1

0

1

21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501

0

1

1

0

1

22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502

1

1

1

0

1

23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503

0

0

0

1

1

24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504

1

0

0

1

1

25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505

0

1

0

1

1

26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506

1

1

0

1

1

27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507

0

0

1

1

1

28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508

1

0

1

1

1

29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509

0

1

1

1

1

30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510

1

1

1

1

1

31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511

Содержание Wizard Extreme

Страница 1: ...Wizard Extreme user manual...

Страница 2: ...acket 7 Lamp housing 8 Swivel locks 9 Focus rod see illustration below right Cover access screws Measurements are in millimeters 2004 Martin Professional A S Denmark All rights reserved No part of thi...

Страница 3: ...lone operation 17 Single unit operation 17 Master slave operation 17 Stand alone settings 19 MC 1 operation 20 MC 1 settings 20 DMX operation 21 DMX modes 21 Setting the DMX mode 24 DMX control addres...

Страница 4: ......

Страница 5: ...light beams A new glass reflector design offers enhanced light output S AF ET Y INF ORM ATI ON Warning This product is not for household use It presents risks of lethal or severe injury due to fire a...

Страница 6: ...ds the maximum service life When replacing the lamp allow the fixture to cool for at least 5 minutes before opening the fixture or removing the lamp Protect your hands and eyes with gloves and safety...

Страница 7: ...ork area whenever installing or removing the fixture UNPACKING The packing material is carefully designed to protect the fixture during shipment always use it to transport the fixture The Wizard Extre...

Страница 8: ...ied electrician if you have any doubts about proper installation Warning For protection from dangerous electric shock the fixture must be grounded earthed The AC mains supply shall have overload and g...

Страница 9: ...n the table above for the local AC supply voltage The terminals are indicated on a label on the top of the transformer 5 On the ballast move the BROWN wire to the terminal listed for the voltage The t...

Страница 10: ...ply or to the 225 V 60 Hz terminal for 60 Hz local AC supply 5 On the transformer move the BROWN wire to the setting as listed in the previous table for the local AC voltage The terminals are indicate...

Страница 11: ...racket so that it lies flat against the back of the fixture and tighten the swivel locks We recommend that you remove the swivel locks and replace them with M8 hexagonal lock nuts these can be supplie...

Страница 12: ...sed for attachment but ensure that the load is distributed evenly 4 Working from a stable platform clamp or fasten the fixture to the structure 5 Install a safety cable that can hold at least 10 times...

Страница 13: ...ixture on the floor Adjust the mounting bracket and tighten both swivel locks 3 Verify that the fixture is stable that it is at least 0 1 meters 4 in from the surface to be illuminated and at least 0...

Страница 14: ...rd multi coupler bracket that is available as an accessory P N 91606008 Instructions for installing Wizard Extreme fixtures on the multi coupler bracket are supplied with the bracket They are also ava...

Страница 15: ...E C T IO N S The Wizard Extreme s XLR data sockets are wired with pin 1 to ground pin 2 to signal cold and pin 3 to signal hot This is compatible with the standard for DMX devices One or more adaptor...

Страница 16: ...t of the next fixture If connecting two fixtures with opposing polarity on pins 2 and 3 insert a phase reversing cable between the two fixtures 4 Continue connecting fixtures output to input Up to 32...

Страница 17: ...tion and you want to connect them to a data link set them as slaves before connecting them to the link If you have a Wizard Extreme set as master and you want to use a different fixture on the data li...

Страница 18: ...rmination plug is simply an XLR connector with a 120 ohm 0 25 W resistor soldered across pins 2 and 3 Setting the master auto trig 1 Set DIP switch pins 2 and 10 to ON 2 Set DIP switch pins 3 5 6 7 8...

Страница 19: ...7 8 9 10 11 Single or master Auto trigger fast movement 0 1 0 0 0 0 0 0 0 1 0 Auto trigger slow movement 0 1 0 1 0 0 0 0 0 1 0 Music trigger fast movement 1 1 0 0 0 0 0 0 0 1 0 Music trigger slow move...

Страница 20: ...not take effect until the fixture has been powered off and on DIP switch pins 6 7 8 and 9 control options that are most useful when operating multiple Wizard Extremes from a single MC 1 Fixtures with...

Страница 21: ...the mirror drum swivel rate and color and gobo wheel change speed 1 channel mode allows control of the built in stand alone features during music trig operation Full details of the 11 channel Wizard e...

Страница 22: ...el pan speed Adjusting this allows you to program fades on controllers without faders If fade times can be programmed on your controller and you use this function turn the speed function off and set m...

Страница 23: ...the speed function off and set mirror drum swivel to tracking by setting channel 7 to zero This channel has no effect if the stand alone program is running Channel 8 provides speed control of the colo...

Страница 24: ...tart channel and the next ten channels If the DMX control address is set to 100 the fixture uses channels 100 110 Channel 111 is available for use as the control address for the next fixture If the Wi...

Страница 25: ...425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300...

Страница 26: ...ty of the Wizard Extreme Cleaning intervals depend on the operating environment Check fixtures regularly and clean if necessary Important Excessive dust smoke fluid and particulate buildup degrades pe...

Страница 27: ...n A 3 Slide the fan out of the fixture housing illustration B 4 When the fan is clear of the housing lift it up for access to the fan blades 5 Remove dust from the fan and grille with a soft brush cot...

Страница 28: ...components to cool completely 2 Remove the fixture cover You may want to remove the lamp for cleaning see the related steps in Installing a lamp in the Wizard Extreme on page 29 3 Vacuum or gently bl...

Страница 29: ...MSD 200 Important Installing any other lamp may damage the fixture Allow the lamp to cool for at least 5 minutes before packing and moving the fixture To avoid possible damage remove the lamp when sh...

Страница 30: ...the Wizard Extreme and select white light with the open gobo Not using a controller flip DIP switch pins 3 and 10 on Flip all other pins off Apply power to the Wizard Extreme After it has reset the f...

Страница 31: ...power is applied the fuse may be spent If the fuse blows repeatedly there is a fault with the unit that requires service by a Martin technician Never bypass the fuse or replace it with one of another...

Страница 32: ...web site at http www martin com The installed firmware version is displayed by the Power and Data LEDs located next to the DIP switches when power is applied to the fixture and all DIP switch pins ar...

Страница 33: ...the fixtures and the MP 2 Wait a few moments for the fixtures to reset 2 Select Read Memory Card from the MP 2 main menu 3 Use the buttons on the right to scroll through the card slots Select the slo...

Страница 34: ...smitting as a master or is defective Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly together Have the defective fixture serviced by a...

Страница 35: ...t No rotation Counter clockwise rotation fast to slow No rotation Narrow shake slow to fast Wide shake slow to fast Random shake 3 0 5 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71...

Страница 36: ...py yins 12 Dot 13 Weave Wheel rotation slow to fast No rotation Remote stand alone music trig and auto trig 6 0 1 2 128 129 255 0 1 50 51 100 Gobo shake No shake Narrow shake slow to fast Wide shake s...

Страница 37: ...19 24 25 30 31 37 38 43 44 49 50 55 56 62 63 68 69 74 75 100 Macros Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Reserved no function 10 0 1 2 255...

Страница 38: ...tion Clockwise rotation slow to fast No rotation Counter clockwise rotation fast to slow No rotation 3 0 5 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71 72 77 78 83 84 89 90 95 96 1...

Страница 39: ...blast 11 Happy yins 12 Dot 13 Weave Wheel rotation slow to fast No rotation Remote stand alone music trig and auto trig 5 0 127 255 0 50 100 Mirror drum swivel pan Max Left Neutral Max Right 6 0 1 2 1...

Страница 40: ...1 20 21 80 81 115 116 140 141 175 176 210 211 255 0 3 4 7 8 31 32 44 45 54 55 68 69 82 83 100 Light off Light on Strobe Slow music trig every 2 seconds Medium music trig every second Fast music trig e...

Страница 41: ...ted surfaces 0 1 m 4 in Minimum clearance around fans and vents 0 1 m 4 in Orientation any Mounting points two slotted six standard 13 mm holes in bracket Rigging options Overhead or wall mounting Flo...

Страница 42: ...and current 120 V 50 Hz 320 W 2 9 A Maximum power and current 120 V 60Hz 310 W 2 7 A Maximum power and current 230 V 50Hz 320 W 1 5 A Maximum power and current 230 V 60Hz 320 W 1 5 A Maximum power and...

Страница 43: ...C US 3M P N 11501502 ACCESSORIES Philips MSD 250 2 lamp P N 97010100 Osram HSD 250 lamp P N 97010103 Philips MSD 200 lamp P N 97010106 Half coupler clamp P N 91602005 Wizard multi coupler for rigging...

Отзывы: