background image

14

Wizard Extreme user manual

 

M U L T I - C O U P L E R   B R A C K E T

Installing multiple Wizard and/or Wizard Extremes can be made easier by
using the Wizard multi-coupler bracket that is available as an accessory
(P/N: 91606008).

Instructions for installing Wizard Extreme fixtures on the multi-coupler
bracket are supplied with the bracket. They are also available in the
Wizard section of the Support area on the Martin website at
http://www.martin.com

Example multi-coupler bracket installations

Содержание Wizard Extreme

Страница 1: ...Wizard Extreme user manual...

Страница 2: ...acket 7 Lamp housing 8 Swivel locks 9 Focus rod see illustration below right Cover access screws Measurements are in millimeters 2004 Martin Professional A S Denmark All rights reserved No part of thi...

Страница 3: ...lone operation 17 Single unit operation 17 Master slave operation 17 Stand alone settings 19 MC 1 operation 20 MC 1 settings 20 DMX operation 21 DMX modes 21 Setting the DMX mode 24 DMX control addres...

Страница 4: ......

Страница 5: ...light beams A new glass reflector design offers enhanced light output S AF ET Y INF ORM ATI ON Warning This product is not for household use It presents risks of lethal or severe injury due to fire a...

Страница 6: ...ds the maximum service life When replacing the lamp allow the fixture to cool for at least 5 minutes before opening the fixture or removing the lamp Protect your hands and eyes with gloves and safety...

Страница 7: ...ork area whenever installing or removing the fixture UNPACKING The packing material is carefully designed to protect the fixture during shipment always use it to transport the fixture The Wizard Extre...

Страница 8: ...ied electrician if you have any doubts about proper installation Warning For protection from dangerous electric shock the fixture must be grounded earthed The AC mains supply shall have overload and g...

Страница 9: ...n the table above for the local AC supply voltage The terminals are indicated on a label on the top of the transformer 5 On the ballast move the BROWN wire to the terminal listed for the voltage The t...

Страница 10: ...ply or to the 225 V 60 Hz terminal for 60 Hz local AC supply 5 On the transformer move the BROWN wire to the setting as listed in the previous table for the local AC voltage The terminals are indicate...

Страница 11: ...racket so that it lies flat against the back of the fixture and tighten the swivel locks We recommend that you remove the swivel locks and replace them with M8 hexagonal lock nuts these can be supplie...

Страница 12: ...sed for attachment but ensure that the load is distributed evenly 4 Working from a stable platform clamp or fasten the fixture to the structure 5 Install a safety cable that can hold at least 10 times...

Страница 13: ...ixture on the floor Adjust the mounting bracket and tighten both swivel locks 3 Verify that the fixture is stable that it is at least 0 1 meters 4 in from the surface to be illuminated and at least 0...

Страница 14: ...rd multi coupler bracket that is available as an accessory P N 91606008 Instructions for installing Wizard Extreme fixtures on the multi coupler bracket are supplied with the bracket They are also ava...

Страница 15: ...E C T IO N S The Wizard Extreme s XLR data sockets are wired with pin 1 to ground pin 2 to signal cold and pin 3 to signal hot This is compatible with the standard for DMX devices One or more adaptor...

Страница 16: ...t of the next fixture If connecting two fixtures with opposing polarity on pins 2 and 3 insert a phase reversing cable between the two fixtures 4 Continue connecting fixtures output to input Up to 32...

Страница 17: ...tion and you want to connect them to a data link set them as slaves before connecting them to the link If you have a Wizard Extreme set as master and you want to use a different fixture on the data li...

Страница 18: ...rmination plug is simply an XLR connector with a 120 ohm 0 25 W resistor soldered across pins 2 and 3 Setting the master auto trig 1 Set DIP switch pins 2 and 10 to ON 2 Set DIP switch pins 3 5 6 7 8...

Страница 19: ...7 8 9 10 11 Single or master Auto trigger fast movement 0 1 0 0 0 0 0 0 0 1 0 Auto trigger slow movement 0 1 0 1 0 0 0 0 0 1 0 Music trigger fast movement 1 1 0 0 0 0 0 0 0 1 0 Music trigger slow move...

Страница 20: ...not take effect until the fixture has been powered off and on DIP switch pins 6 7 8 and 9 control options that are most useful when operating multiple Wizard Extremes from a single MC 1 Fixtures with...

Страница 21: ...the mirror drum swivel rate and color and gobo wheel change speed 1 channel mode allows control of the built in stand alone features during music trig operation Full details of the 11 channel Wizard e...

Страница 22: ...el pan speed Adjusting this allows you to program fades on controllers without faders If fade times can be programmed on your controller and you use this function turn the speed function off and set m...

Страница 23: ...the speed function off and set mirror drum swivel to tracking by setting channel 7 to zero This channel has no effect if the stand alone program is running Channel 8 provides speed control of the colo...

Страница 24: ...tart channel and the next ten channels If the DMX control address is set to 100 the fixture uses channels 100 110 Channel 111 is available for use as the control address for the next fixture If the Wi...

Страница 25: ...425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300...

Страница 26: ...ty of the Wizard Extreme Cleaning intervals depend on the operating environment Check fixtures regularly and clean if necessary Important Excessive dust smoke fluid and particulate buildup degrades pe...

Страница 27: ...n A 3 Slide the fan out of the fixture housing illustration B 4 When the fan is clear of the housing lift it up for access to the fan blades 5 Remove dust from the fan and grille with a soft brush cot...

Страница 28: ...components to cool completely 2 Remove the fixture cover You may want to remove the lamp for cleaning see the related steps in Installing a lamp in the Wizard Extreme on page 29 3 Vacuum or gently bl...

Страница 29: ...MSD 200 Important Installing any other lamp may damage the fixture Allow the lamp to cool for at least 5 minutes before packing and moving the fixture To avoid possible damage remove the lamp when sh...

Страница 30: ...the Wizard Extreme and select white light with the open gobo Not using a controller flip DIP switch pins 3 and 10 on Flip all other pins off Apply power to the Wizard Extreme After it has reset the f...

Страница 31: ...power is applied the fuse may be spent If the fuse blows repeatedly there is a fault with the unit that requires service by a Martin technician Never bypass the fuse or replace it with one of another...

Страница 32: ...web site at http www martin com The installed firmware version is displayed by the Power and Data LEDs located next to the DIP switches when power is applied to the fixture and all DIP switch pins ar...

Страница 33: ...the fixtures and the MP 2 Wait a few moments for the fixtures to reset 2 Select Read Memory Card from the MP 2 main menu 3 Use the buttons on the right to scroll through the card slots Select the slo...

Страница 34: ...smitting as a master or is defective Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly together Have the defective fixture serviced by a...

Страница 35: ...t No rotation Counter clockwise rotation fast to slow No rotation Narrow shake slow to fast Wide shake slow to fast Random shake 3 0 5 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71...

Страница 36: ...py yins 12 Dot 13 Weave Wheel rotation slow to fast No rotation Remote stand alone music trig and auto trig 6 0 1 2 128 129 255 0 1 50 51 100 Gobo shake No shake Narrow shake slow to fast Wide shake s...

Страница 37: ...19 24 25 30 31 37 38 43 44 49 50 55 56 62 63 68 69 74 75 100 Macros Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Reserved no function 10 0 1 2 255...

Страница 38: ...tion Clockwise rotation slow to fast No rotation Counter clockwise rotation fast to slow No rotation 3 0 5 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71 72 77 78 83 84 89 90 95 96 1...

Страница 39: ...blast 11 Happy yins 12 Dot 13 Weave Wheel rotation slow to fast No rotation Remote stand alone music trig and auto trig 5 0 127 255 0 50 100 Mirror drum swivel pan Max Left Neutral Max Right 6 0 1 2 1...

Страница 40: ...1 20 21 80 81 115 116 140 141 175 176 210 211 255 0 3 4 7 8 31 32 44 45 54 55 68 69 82 83 100 Light off Light on Strobe Slow music trig every 2 seconds Medium music trig every second Fast music trig e...

Страница 41: ...ted surfaces 0 1 m 4 in Minimum clearance around fans and vents 0 1 m 4 in Orientation any Mounting points two slotted six standard 13 mm holes in bracket Rigging options Overhead or wall mounting Flo...

Страница 42: ...and current 120 V 50 Hz 320 W 2 9 A Maximum power and current 120 V 60Hz 310 W 2 7 A Maximum power and current 230 V 50Hz 320 W 1 5 A Maximum power and current 230 V 60Hz 320 W 1 5 A Maximum power and...

Страница 43: ...C US 3M P N 11501502 ACCESSORIES Philips MSD 250 2 lamp P N 97010100 Osram HSD 250 lamp P N 97010103 Philips MSD 200 lamp P N 97010106 Half coupler clamp P N 91602005 Wizard multi coupler for rigging...

Отзывы: