INSTALLATION
9. At this time the spa should have water flowing from the jets. If
the pump has not primed and the water is not flowing from the jets
after two minutes TURN OFF POWER TO THE SPA and vent air from
the pumps by slightly opening the pump unions located behind the
equipment door. After turning the power on again, the spa initiates a
new priming mode. Repeat steps above.
10. The system requires approximately two minutes of water flow to
determine the water temperature. After two minutes of water flow, the
temperature is displayed as actual water temperature. After you have
manually exited the priming mode (or allowed the spa to automatically
exit) the LCD window momentarily displays 100°F (38°C) and then the display switches to - -
°F.
11. The factory default setting for water temperature is 100°F (38°C). Use the TEMP pads on the
control panel to set the water temperature to the desired level. (See SPA CONTROL OPER-
ATION.) It takes up to 24 hours to heat the water to desired temperature depending on the
water temperature and voltage of your spa.
Test the water for the proper chemical balance and adjust as necessary. Marquis
®
SpaCare
products are recommended. (See
WATER TREATMENT
.)
PROPER CHEMICAL BALANCE IS
IMPORTANT
for your safety and the longevity of your spa.
Vent air by slightly opening pump
unions.