INSTALLATION
• Permanently connected (Hard wired).
• Rated 240V, 60Hz, 50A, three wires (#6 copper) plus ground (#8 copper (8.42mm
2
)), [4 wires
total].
• Circuit breaker or fuse size: 50A.
• A disconnecting means must be installed within sight from the equipment and at least 5 feet
(1.52m) from the inside walls of the spa.
• Connect only to a circuit protected by a Class A ground Fault Circuit Interrupter (GFCI).
Red (hot) wire connected to #2 on terminal block.
Black (hot) wire connected to #3 on terminal block.
White (neutral) wire connected to #4 on terminal block.
Green (ground) wire routed through plastic enclosure and secured to exterior bonding lug.
Improperly wired spas are beyond Marquis Corp. control and are not covered under the warranty.
Other items beyond Marquis Corp. control include, but are not limited to, damage resulting from:
improper connections; accidents; failure to follow procedures and instructions defined in the Marquis
®
printed in
structions; cleaning agents; and natural occurrences including but not limited to rodent
or insect infestation, mold, lightning and other acts of nature.
12
Содержание Crown Resort
Страница 17: ...SUMMIT THERAPY ZONES ZONE 1 ZONE 2 ZONE 3 ZONE 4 HK20 HK20 H O T ZONE REGAL THERAPY JETS 17...
Страница 19: ...RESORT THERAPY ZONES Neck jets operate in all zones RESORT THERAPY ZONES ZONE 1 ZONE 3 ZONE 2 ZONE 2 19...
Страница 21: ...SPIRIT THERAPY ZONES Zone 1 Zone 2 SPIRIT Therapy Control Zone Diagram 21...