INSTALLATION
SUCTION GUARDS
The suction guard(s) in the footwell of your spa is an opening through
which the jet pump(s) draws water. The suction fittings have an inte-
grated vacuum release built into them. In the event that a suction fitting
gets blocked, air will be induced causing the pump to cavitate and the
water flow interrupted. Once the blockage is removed, normal operation
will resume. Suction fittings are equipped with a safety guard. Suction
through the fittings can be strong. The safety guard(s) must remain in
place and undamaged. A fitting with a damaged guard(s) can be danger-
ous, especially to small children or people with long hair. Should any part
of the body become drawn to a fitting, turn the jet pump(s) off immediately. Long hair should
be restrained. Never allow long hair to float freely in the spa. Replace any missing or damaged
suction guard(s).
NOTE:
It is normal for the flow rates of the suction fittings to vary from strong to barely notice-
able.
ELECTRICAL REQUIREMENTS
It is the responsibility of the spa owner to ensure that all electrical connections are made by a quali-
fied electrician in accordance with all national, state, and local electrical codes in effect at the time of
installation. Fuses are covered to be free of defect at time of installation only.
240 Volt
All connections must be made in accordance with the wiring diagram found on the inside of the
control box cover. Connections must be made with copper conductors only
– do NOT use alumi-
num wire
.
All conductors, circuit breakers, and fuses and the GFCI must be sized in accordance
to the total amperage load as specified below.
Improperly wired spas can cause irreversible damage resulting in blown fuse and melted terminal
block, and to other electrical components. Also, damage caused to components or equipment
caused by high or low voltage, brown outs or electric surges is not covered under warranty.
Safety guard of suction fitting
must remain in place.
11
Содержание Crown Resort
Страница 17: ...SUMMIT THERAPY ZONES ZONE 1 ZONE 2 ZONE 3 ZONE 4 HK20 HK20 H O T ZONE REGAL THERAPY JETS 17...
Страница 19: ...RESORT THERAPY ZONES Neck jets operate in all zones RESORT THERAPY ZONES ZONE 1 ZONE 3 ZONE 2 ZONE 2 19...
Страница 21: ...SPIRIT THERAPY ZONES Zone 1 Zone 2 SPIRIT Therapy Control Zone Diagram 21...