MWUH
Horizontal / Vertical
Unit Heater
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:
1.
Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a rep-
utable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel.
7.
Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
12. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
13. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
IMPORTANT INSTRUCTIONS
ECR 39427
09/12
5200-11173-000
Table 1. Specifications
Amps
BTU/hour
240V
208V
CFM
Rise
240V
208V
MWUH5004A
(Can be operated at 208V See Table 2 for output ratings)
* 5000 W @ 240/208V - 1 - 60
20.9
24.0
270
60˚F
17,065
12,799
4165 W @ 240/208V - 1 - 60
17.4
20.0
270
60˚F
14,215
10,659
3332 W @ 240/208V - 1 - 60
13.9
16.0
270
60˚F
11,365
8,533
2500 W @ 240/208V - 1 - 60
10.4
12.0
270
60˚F
8,533
6,393
MWUH5008A
* 5000 W @ 208V - 1 - 60
-
24.0
270
60˚F
-
17,065
4165 W @ 208V - 1 - 60
-
20.0
270
60˚F
-
14,215
3332 W @ 208V - 1 - 60
-
16.0
270
60˚F
-
11,365
2500 W @ 208V - 1 - 60
-
12.0
270
60˚F
-
8,533
*Heater is shipped from factory wired for these wattages. Heater can be field adjusted to the
other wattages.