Marley CSLAL Скачать руководство пользователя страница 8

12/10

Part No. 5200-2210-002

ECR 38636

LIMITED WARRANTY

All  products  manufactured  by  Marley  Engineered  Products  are  warranted  against  defects  in  workmanship  and  materials  for  one  year  from  date  of  installation,  except 
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from
accident,  misuse,  or  alteration;  nor  where  the  connected  voltage  is  more  than  5%  above  the  nameplate  voltage;  nor  to  equipment  improperly  installed  or  wired  or 
maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products
to Marley Engineered Products Service Center. Within the limitations  of this warranty, inoperative units should be returned to the nearest Marley authorized service cen-
ter or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that
such repair or replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS  AGREEMENT.  MARLEY  ENGINEERED  PRODUCTS SHALL  NOT  BE  LIABLE  FOR  CONSEQUENTIAL  DAMAGES  ARISING  WITH  RESPECT  TO  THE 
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the fac-
tory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization,
include all catalog numbers shown on the products.

470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

HOW TO OBTAIN WARRANTY SERVICE AND 
WARRANTY PARTS PLUS GENERAL INFORMATION

1. Warranty Service or Parts

1-800-642-4328

2. Purchase Replacement Parts

1-800-654-3545

3. General Product Information

www.marleymep.com

Note: When obtaining service always have the following:

1. Model number of the product
2. Date of manufacture
3. Part number or description

Description

Part Number

Mercury relay, 1 pole 30 amps, 24 Volt coil

5018-7050-001

Mercury relay, 1 pole 60 amps, 24 Volt coil

5018-7049-001

Mercury relay, 1 pole 30 amps, 120 Volt coil

5018-7050-002

Mercury relay, 1 pole 60 amps, 120 Volt coil

5018-7049-002

Mercury relay, 1 pole 30 amps, 208 Volt coil

5018-7050-003

Mercury relay, 1 pole 60 amps, 208 Volt coil

5018-7049-003

Mercury relay, 1 pole 30 amps, 240 Volt coil

5018-7050-004

Mercury relay, 1 pole 60 amps, 240 Volt coil

5018-7049-004

Mercury relay, 1 pole 30 amps, 277 Volt coil

5018-7050-005

Mercury relay, 1 pole 60 amps, 277 Volt coil

5018-7050-005

Circuit breaker, 2 pole 30 amps

1226-7009-013

Circuit breaker, 2 pole 60 amps

1226-7009-010

Circuit breaker, 3 pole 30 amps

1226-7009-005

Circuit breaker, 3 pole 60 amps

1226-7009-002

24V Transformer, 120 Volt primary

5814-7017-007

24V Transformer, 208 Volt primary

5814-7017-002

24V Transformer, 240 Volt primary

5814-7017-007

24V Transformer, 277 Volt primary

5814-7017-001

Disconnect Switch

5216-0124-000

Thermostat, 1 pole

5813-0024-000

Thermostat, 2 stage

5813-0023-000

Pneumatic Control

5216-7027-001

Renewal Parts Identification: Optional Controls: CSLAMBCS, CSLALBCS

Содержание CSLAL

Страница 1: ...ower supply circuit coming to heater is disconnected at main disconnect or service panel before installing or servicing this heater 7 This heater is not for residential or household use except model C...

Страница 2: ...V 277V Number L Watts Ft Watts 1 3 1 3 1 2125 125 250 1 2 1 0 0 9 2188 188 375 1 8 1 6 1 4 2250 250 500 2 4 2 1 1 8 2375 28 375 750 3 6 3 1 2 7 2500 500 1000 4 8 4 2 3 6 2564 564 1125 5 4 3 1 4 7 2 7...

Страница 3: ...an electrical convenience receptacle outlet CAUTION Heater operates at high temperatures Keep elec trical cords including telephone and computer cables drapes and other furnishings away from heater F...

Страница 4: ...locations remove the filler section and drill the required mounting holes Install the filler section in the heater and the end cap on the filler section as shown in Figure 3 Note If a thermostat and...

Страница 5: ...with corner section Refer to Figure 6 6 Install end caps 6 on the outer end of the last heater 7 and 9 using four 6 screws supplied with end caps Refer to Figure 5 for details of end cap installation...

Страница 6: ...e accumulated inside heater around element fins If heater must be disassembled for cleaning use care when cleaning element fins to avoid damaging fins 4 After cleaning and servicing always reassemble...

Страница 7: ...060 066 072 077 081 277 Volts 049 055 061 067 073 078 082 188 W ft 120 Volts 005 011 017 023 029 per 208 Volts 002 008 014 020 026 032 036 Element 240 Volts 001 007 013 019 025 031 035 277 Volts 000 0...

Страница 8: ...y not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For the address of your nearest authorized service center contact Mar...

Страница 9: ...o de alimentaci n el c trica del calefactor est desconectado en el tablero de ser vicio o desconectador principal antes de instalar o prestar servicio a este calefactor 7 Este calefactor no es para us...

Страница 10: ...5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Modelo CSLAS H 5 1 2 D 3 Tabla A Tabla A continuaci n Corriente A N mero de Longitud Watts 208 V 240 V 277 V cat logo L Watts pie tot...

Страница 11: ...onan con los juegos 6 No instale el calefactor debajo de un tomacorriente el ctrico PRECAUCI N el calefactor funciona a altas temperaturas Mantenga los cordones el ctricos incluidos los cables de tel...

Страница 12: ...tir el acceso a estos controles Figura 3 5 Coloque el gabinete del calefactor en la pared para verificar la uni formidad de la misma No lleve el calefactor contra una superficie de pared que sea irreg...

Страница 13: ...la instalaci n de las tapas extremas consulte la Figura 5 7 Perfore los agujeros de montaje del tama o requerido en todos los gabinetes de los calefactores Nota en cada caja de conexiones se proporcio...

Страница 14: ...cionando correcta mente Nota importante existen dispositivos de seguridad incorporados que se suministran dentro de los calefactores incluidos uno o m s controles de l mite de sobretemperatura protect...

Страница 15: ...5 096 elemento 240 volts 048 054 060 066 072 077 081 277 volts 049 055 061 067 073 078 082 188 W pie 120 volts 005 011 017 023 029 por 208 volts 002 008 014 020 026 032 036 elemento 240 volts 001 007...

Страница 16: ...rse a su caso Esta garant a le da derechos legales espec ficos y usted puede tener tambi n otros derechos que var an de un esta do o jurisdicci n a otro Para obtener la direcci n de su centro de servi...

Страница 17: ...voire mortelle peut r sulter d une commotion lectrique Assurez vous que le circuit du secteur d alimentation lectrique arrivant au radiateur est bien d branch en amont l interrupteur g n ral ou au pan...

Страница 18: ...d le CSLAS H 5 1 2 D 3 Tableau A Tableau A suite Amp rage N du longueur Total en 208 V 240 V 277 V catalogue L Watts pied Watts 1 3 1 3 1 2125 125 250 1 2 1 0 0 9 2188 188 375 1 8 1 6 1 4 2250 250 500...

Страница 19: ...g es par le feu il faut utiliser des kits d espacement de cat gorie de r f rence S01 ou S02 Consultez les instructions livr es avec ces kits 6 N utilisez pas le radiateur sous une prise d alimentation...

Страница 20: ...arter pour supporter le poids des radiateurs de grande longueur 6 et plus Ne percez aucun trou de montage additionnel dans les bo tiers de raccordement 5 Positionnez le carter du radiateur sur le mur...

Страница 21: ...s d extr mit 6 sur le bout ext rieur du dernier radiateur 7 et 9 au moyen de quatre vis 6 fournies avec ces capuchons d extr mit R f rez vous la Figure 5 pour les d tails d installation de ces capucho...

Страница 22: ...nt des unit s Remarque importante Il y a des dispositifs de s curit int gr s dans les radiateurs incluant un ou plusieurs contr les de d passement de limite de temp rature protection thermique consult...

Страница 23: ...r 208 Volts 086 088 090 092 094 095 096 l ment 240 Volts 048 054 060 066 072 077 081 277 Volts 049 055 061 067 073 078 082 188 W pied 120 Volts 005 011 017 023 029 par 208 Volts 002 008 014 020 026 03...

Страница 24: ...st possible que les exclusions et restrictions ci dessus ne s ap pliquent pas vous Cette garantie vous accorde des droits juridiques sp cifiques mais il est possible que vous ayez galement d autres dr...

Отзывы: