DigiConvert Operating Instructions
Copying this document, or disclosing it to third parties is not allowed without our approval. This document must not be used in any abusive way by the receiver or third
parties. Fe Vogt GmbH
DigiConvert Operating Instructions
33 of 79
FMS monitoring
The force measurement system is used to
measure the manually set pressure of the yoke.
FMS monitoring alarms or stops the machine if
the measured value is outside the valid range.
Current measurement
Action
OFF
Monitoring is deactivated
Alarm
Leaving the valid value range
triggers an alarm message.
STOP
Leaving the valid value range stops
the machine
Alarm+
Stop
Combination of the setting alarm
and STOP.
Alarm
The settings for an alarm are made
in this line.
STOP
The settings for a machine stop are
made in this line
Type of threshold value
Not
OK
OK
Threshold value
,
(Inv.)
Defines an "OK" or "not OK"
threshold for the signal.
,
(Inv.)
Defines an "OK" or "not OK" range
for the signal.
,
(Inv.)
Defines an "OK" or "not OK"
hysteresis range for the signal.
Inv.
Inverts the threshold value type
Threshold value
Specification of threshold values. The number of
values that can be entered depends on the set
threshold value type.
OK, NOK
Delay period in [s]. The signal must be "OK" or "not
OK" for this time for the corresponding action to be
triggered or revoked.