40 - Installation manual - Ecotype
3.10
What is to be done, when the electric operated handling system doesn’t work?
WARNING!
It is forbidden to open the Control Box by removing the bottom cover.
Tampering will void the warranty.
3.10.1 Replacement of the internal fuse in emergency case
Prior to replace the internal fuse Check that the external one placed on the positive pole
terminal of the battery hasn’t blown.
Otherwise that is the fuse which needs to be replaced.
IMPORTANT INFORMATION FOR USER SAFETY
The replacement of the internal fuse in emergency case should be executed by the operator only as an
exception, advising to contact as a matter of priority, if the emergency situation allows it, the local
installer for getting detailed information about the procedure to apply
.
CAUTION!
Before opening the cover of the contacts of the Control Unit, disconnect the battery to isolate the unit..
WARNING!
This procedure must be absolutely performed by qualified personnel to avoid invalidation of warranty!
1. Using a suitable screwdriver, loosen the screws on the sides of the cable cover on the left side of the Control Box.
2. Remove the cover while taking care not to damage its gasket.
3. Replace the blown fuse (F).
4. Wait at least 8 hours before reclosing the cover, as the gasket needs a sufficient time to recover it shape. When closing
the cover, be careful not to damage the gasket.