3 INSTALLATION
The panel box contains high voltage
components. Only authorized service
personnel should be allowed inside.
See Lock-Out & Tag-Out instructions in
the Maintenance section.
ELECTRICAL INSTALLATION
WARNING:
BEFORE MAKING ANY ELECTRICAL CONNECTION, BE SURE
THAT THE DISCONNECT SWITCH HAS BEEN LOCKED-OUT AND TAGGED-OUT
PER THE LOCK-OUT AND TAG-OUT INSTRUCTIONS ON PAGE 2-1.
1.
BRANCH CIRCUIT PROTECTION IS NOT PROVIDED WITH THIS UNIT,
AND MUST BE PROVIDED BY THE INSTALLER.
Use the FUSE AND
CIRCUIT BREAKER chart and the WIRE SIZE chart in the MAINTE-
NANCE section of this manual for reference during the electrical installa-
tion.
2.
Before connecting power to the baler, check the incoming line voltage
with a voltmeter. Also, check voltage wiring in the baler panel box. If the
baler is not wired to the proper voltage, make necessary corrections
before proceeding.
3.
A lockable disconnect switch
IS PROVIDED
, in the panel box, on models
V-4830HD, V-6030HD, V-7230HD, V-6030LP, and, V-6042LP, and is sized
in accordance with the baler. Three phase power should be connected to
the top of this switch (a single phase option is also available). Be careful
not to let incoming wires touch each other. A properly sized equipment
ground wire should be connected to the enclosure ground lug.
4.
A lockable disconnect switch
IS NOT PROVIDED
on models V-4830 &
V-6030, and must be provided by the installer at the time of installation.
This disconnect switch must be fussed, lockable, and within sight of, and
not to exceed 50 feet from the baler, per the National Electrical Code.
Additional local codes may apply.
3-3
CAUTION: All equipment should be grounded per the National Electric Code.