4. Once the laminate has filled up the area in front of the metering rod and starts running
off both sides of the media lower the heater, switch on the drying fans and then start the
drive motor at the 2.5 position. Once the media begins to coat and move adjust the speed
to the 3 position as the heater reaches 100 deg. Celsius.
5. Once the laminate reclaiming tray begins to fill up some start the peristaltic laminate
pump.
a. Start the laminate pump by switching the toggle switch up to the on position.
b. Turn the pump speed control knob so that it clicks on and adjust it to the 20%
or 1/4 position.
c. It is ideal to have the pump recycle the liquid without entirely draining the
reclaiming trough. (Running the laminate reclaiming trough dry will cause the
filter screen to dry out and clog)
Siphon from Drum with Peristaltic Pump:
1. Make sure the fluid reservoir valve is in the "off" position.
2. Switch the top valve to the laminating position. Switch the bottom two remaining
valves to the cleaning position.
3. Hook the siphoning hose to the inlet connector on the inside bottom left of the machine
(when facing the cleaning trough) just behind the cleaning trough.
4. Connect the other end of the siphoning hose to the siphoning drum connector in the
drum and loosen the other drum bung so air can ventilate through into the drum.
5. Turn the laminating power switch to the up (forward) position. Adjust the pump to the
desired speed using the rotary knob (Speed Controller).
6. Switch the rotary knob (Speed Controller) to the "off" position once the fluid reservoir
is filled to just under the fluid inlet port.