Interface with external turbo timers 

 

When this feature is turned ON, the system allows the vehicle to run on an external turbo timer for a time that does 
not exceed the time programmed into the system. The system allows for 1 minute, 2 minutes or 4 minutes.  
 
IT IS VERY IMPORTANT THAT THE EXTERNAL TURBO TIMER DOES NOT RUN FOR LONGER THAN THIS TIME 
AS IT WILL CAUSE THE SYSTEM TO FALSE ALARM. 
 
How to set up the turbo timer feature and set the maximum run time: 
 
1.

 

Install the alarm as normal except connect the IGN input from the alarm to the vehicles accessory circuit instead 
of  true  ignition.  This  wire  must  drop  to  0v  when the key is turned off and the vehicle is running on the turbo 
timer. 

 

2.

 

Ensure all doors, bonnet and boot are closed.  

 

3.

 

Turn the ignition on, off and on then press the 

 button 16 times. The indicators, LED and siren will flash or 

chirp upon each press of the button. 

 

4.

 

Now turn the ignition off. The siren should chirp the current run time setting to indicate that the programming 
mode has been entered.

 

5.

 

Pressing  the 

 

button  will  increment  the  maximum  run  time  allowed  for  the  turbo  timer.  There are four 

levels,  each  level  is  indicated  by  the  number  of  chirps.  See  table  below.  It  is  very  important that the external 
turbo timer does not run for longer than the maximum run time set below as the system will false alarm. 

 

Number of chirps 

Turbo timer run time 

1 minute 

2 minutes 

4 minutes 

10 seconds 

 

7.

 

Once  the desired time duration is selected simply turn the ignition on then off. The siren should chirp the new 
run time setting indicating the turbo timer time duration is now set. 
 

No  other  programming  is  required  to  run  an  external  turbo  timer.  However  when  using  an  external  turbo timer, 
ensure  that  the  Onboard  Turbo  Timer  feature  in  Register  1,  Feature  17  is  turned  off  (factory  set  off).  Once  the 
maximum  time  is  programmed,  the  cars ignition may be controlled by an external turbo timer. The external turbo 
timer must not run longer than the time set above or the system will false alarm. 
 
Operation: 
To operate the system simply turn the ignition off and exit the vehicle as normal. 

 

Pressing the 

 button will arm the alarm and lock the doors as normal but the immobiliser relays will stay closed 

until the pre-programmed time out. 

 

If the alarm detects an intrusion the alarm will sound and the system will immobilise the engine.  

Содержание AVS 4401765

Страница 1: ...XF2106 R2 This product complies with AS NZS 3749 1 2003 Class A Volumetric Sensing glass break shock must be enabled to comply with a Class A installation refer Programmable Features Class A VSAS Veh...

Страница 2: ...ons Operate system from car s factory remote Anti hijack modes Courier feature Automatic re arm and re lock 4 5 Additional features Data battery back up siren V2 Intelligent glass break sensor AVS A5...

Страница 3: ...1 continued Turbo timer run time On board turbo timer Delayed panic MAP Feature 2 second entry delay Factory remote interface for old OEM Enhancement module Courier mode 15 16 Programming features Re...

Страница 4: ...on all inputs and outputs except the immobiliser circuits If the poly fuse detects an overload it will open to prevent damage to the alarm components Once the overload has been removed the polyfuse w...

Страница 5: ...d four times upon disarming Low remote battery warning When the battery in the remote is almost flat the remotes LED will flash instead of lighting constantly when a button is pressed Panic car finder...

Страница 6: ...timer allows the vehicle to run for 1 2 or 4 minutes after the ignition is switched to off Interface will interface with an external turbo timer to allow the vehicle to run on the turbo timer after th...

Страница 7: ...re is disconnected If the alarm is armed or auto immobilised the siren WILL sound if the battery or digital data wire is disconnected Original DBBSM sirens can be used on V5 alarm modules but will beh...

Страница 8: ...vailable sequence above 2 A new remote can be coded into the system 12 times You can do this by coding the same remote in even if you only have one remote 3 Or the unit can be sent back to Manta Elect...

Страница 9: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 9 NOTE Unless a remote control is learnt in you will need to repeat the procedure every time you wish to start the car...

Страница 10: ...ate it is possible to trace the required wires by first un clipping the case Next slide the circuit board out to expose the main connector plug Use the following connector diagram below to trace each...

Страница 11: ...her alarm wires marked with red and white sheathing Green this wire gives a constant 200mA negative output alarm when the alarm is triggered It can be used to run additional piezo sirens or to activat...

Страница 12: ...gives a 1 second negative output for boot release 150ma maximum For use where electric boot release is to be connected Extra components may be required depending on the vehicle Refer to Remote Boot R...

Страница 13: ...allation standards make sure the cut is made more than 300mm from the starter or fuel pump immobiliser cuts IM3A 2 wires and IM3B 2 wires Fuel pump immobiliser circuit The fuel pump wire usually runs...

Страница 14: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 14...

Страница 15: ...1 Vehicle set up Close all doors bonnet boot arm disarm alarm then turn ignition on off on Feature Arm and disarm chirp Press the button this many times 2 Factory setting ON Description One chirp on a...

Страница 16: ...AVS A SERIES INSTALLATION MANUAL GEN 2 VER 5 16...

Страница 17: ...on This mode allows the installer to verify that each trigger of the alarm system is working without having to arm and disarm the system each time and setting off the siren After pressing the button 1...

Страница 18: ...ne thermo fans cut in automatically or there are other accessories active even when the ignition is turned off e g car phones TO ACTIVATE VOLTAGE DROP TURN FEATURE OFF Feature Turbo timer run time Pre...

Страница 19: ...onds after pressing the button If the alarm is activated the system will shut the engine down and trigger as normal When in courier mode the glass sensor AVS A5 will be disabled while the engine is ru...

Страница 20: ...turned ON the unlock output becomes a 15 second negative pulse instead of 0 5 seconds This feature is for use with vehicles with vacuum central locking Feature Anti Hijack Mode 1 Press the button this...

Страница 21: ...larm will also activate for five minutes after the anti hijack trigger can be turned off via Register 2 Feature 11 Feature Alarm on Anti Hijack trigger Press the button this many times 11 Factory sett...

Страница 22: ...t ensure the cooling fans continue to run when the vehicle is running on the turbo timer you may need to hook up the second ignition wire relay as per next page Note IM2A MUST BE CONNECTED TO 12V MAIN...

Страница 23: ...STALLATION MANUAL GEN 2 VER 5 23 6 Once the desired time duration is selected simply turn the ignition on then off The siren should chirp the new run time setting indicating the turbo timer time durat...

Страница 24: ...l arm the alarm and lock the doors as normal but the immobiliser relays will stay closed until the pre programmed time out If the alarm detects an intrusion the alarm will sound and the system will im...

Страница 25: ...ement the maximum run time allowed for the turbo timer There are four levels each level is indicated by the number of chirps See table below It is very important that the external turbo timer does not...

Страница 26: ...switch to disarm the alarm Inhibit mode is a much more secure upgrade option The table below describes each upgrade wires operation Wire Inhibit mode Enable mode POS1 Positive arm arms the alarm when...

Страница 27: ...gnition on then off and the momentary switch is pressed or pin code is entered Mode 1 In mode 1 the unit will enter anti hijack countdown following the opening of a door when the ignition is on Upon e...

Страница 28: ...er as normal When in courier mode the glass sensor AVS A5 will be disabled however AUX input remains active when the engine is running but will arm normally when the ignition is off Note The ignition...

Страница 29: ...ehicle Connect to lock wire of vehicle 2 Positive pulse CDL system Cut Cut Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Earth Earth Connect to unlock wire of vehicle Connect to lock wire of...

Страница 30: ...stem Unlock NC Unlock COM Unlock NO Lock NC Lock COM Lock NO Vehicle s Existing CDL Switch Vehicle s Existing Door Motor Cut Cut Earth Connect to relay side of control wire Connect to Unlock COM 5 Sin...

Страница 31: ...4 The RCX 4 can also receive these signals and will put out a basic low current negative Note If you want to use the alarm boot pop or alarm panic channel be aware that Ch 2 on the RXPRO or RCX 4 wil...

Страница 32: ...yfuse may have tripped Check circuit for excessive current draw or short Polyfuse may take several minutes before resetting Wait and re test Turbo timer problems No engine shut down on boot button Eng...