AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
15
Changing programmable features
The AVS A-Series programming mode is very quick and easy to use. Follow the steps below to change any of the
programmable features:
1.
Find the Register (1 or 2) in which the feature is located.
2.
Set the vehicle up as described to access the required Register. e.g. to access Register 1 close all doors,
bonnet and boot, arm and disarm alarm then turn ignition on, off and back on.
3.
Press the
button on the remote the number of times for the function you wish to change.
e.g. for arm and disarm chirps press the
button two times. Each press of the button will be confirmed
by a flash of the indicators and dash LED and a chirp from the siren if connected.
4.
Turn the ignition off.
5.
The system will then confirm whether the feature is on or off. If the feature is enabled (turned on) the siren
will chirp once. If the feature is disabled (turned off) the siren will chirp twice.
Programming features Register 1
Vehicle set up: Close all doors, bonnet & boot, arm & disarm alarm then turn ignition on, off & on.
Feature:
Arm and disarm chirp
Press the
button
this many times:
2
Factory setting:
ON
Description:
One chirp on arm and two chirps on disarm.
Feature:
No door ajar warning
Use if the car has factory interior light delay
Press the
button
this many times:
4
Factory setting:
OFF
Description:
When this feature is ON, the door ajar warning feature is removed so the indicators and
siren will not chirp for three seconds if the door is left open. It will ignore the door,
bonnet/boot & aux circuits for 45 seconds upon arming.
Feature:
Instant boot release/On board turbo timer shut down
Press the
button
this many times:
6
Factory setting:
OFF
Description:
When this feature is ON, the boot release button will only require pressing once rather
than holding down for three seconds to open an electric boot or shut down the On-
board turbo timer before the preset time.
Feature:
Negative on alarm/pager out
Press the
button
this many times:
7
Factory setting:
OFF
Description:
When this feature is ON, the –ARM wire changes to become ‘negative on alarm’ instead.
Can be used to power pagers or internal sirens.