DKR Drive Controllers
Service and checks
11-3
DOK-DIAX03-DKR********-PR02-EN-P
Check whether the condition as supplied of the replacement device
complies with the condition of the faulty device with regard to the cooling
system.
DKR02 and DKR03:
Verify the conversion criteria by means of
the instructions in chapter “Adapting the cooling method“ from page 10-1.
DKR04:
Verify the conversion criteria by means of the instructions in
chapter “Adapting the cooling method“ from page 10-3.
CAUTION
Hand injuries caused by heavy drive controller
with sharp-edged housing!
⇒
Use appropriate hoisting gear and protective gloves
for installation.
⇒
By means of appropriate hoisting gear, attach the drive controller to
the loosened fixing screws. Tighten the screws!
⇒
In accordance with the machine manufacturer’s specification,
reestablish all electrical connections and, if necessary, the connections
for liquid cooling or duct cooling for the drive controller.
⇒
In accordance with the machine manufacturer’s instructions, put the
machine into service again.
⇒
Control the functions and cooling system of the drive controller! After
putting liquid-cooled drive controllers into service you have to control
the level of the cooling agent in the tank!
Convert cooling type of
controller, if necessary
Install controller
Connect controller
Put controller into service again
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01