4-2
Technical data
DKR Drive Controllers
DOK-DIAX03-DKR********-PR02-EN-P
Ambient conditions
Perm. ambient temp. range with rated
data
T
A1
°C
+5 ... +45
Max. perm. ambient temp. with derating
of nominal data to 80%
T
A2
°C
+55
Storage and shipping temperature
T
L
°C
-30 ... +80
Max. installation elevation without
nominal data derating
m/sea lev.
0 ... 1000
Protection category
IP 20 per EN60529 / IEC529
*:
Tact frequency of the power section
Fig. 4-1:
Technical data DKR02
4.2 DKR03
Designation of the drive controller
Designation
Symbol
Unit
DKR03.1-W100-...
DKR03.1-F100-...
DKR03.1-W200-...
DKR03.1-F200-...
Rated power voltage
U
N1
V
3xAC 400 ... 480,
±
10%
System frequency
f
N1
Hz
50 ... 60
Control voltage
U
N2
V
AC 230 V,
±
10%
Control voltage frequency
f
N2
Hz
50 ... 60
Control voltage power
P
N2
VA
200
Continuous current of the drive
(4 kHz/8 kHz)*
I
conteff
A
4 kHz: 71
8 kHz: 60
4 kHz: 92
8 kHz: 78
Peak current of the drive
I
maxeff
A
71
141
Continuous power of the drive
(4 kHz/8 kHz)*
(as relates to the driven shaft of motor,
at 3xAC 400 V, -5%)
P
cont
kW
4 kHz: ca. 26
8 kHz: ca. 22
4 kHz: ca. 35
8 kHz: ca. 30
Peak power of the drive (4 kHz/8 kHz)*
(as relates to the driven shaft of motor,
at 3xAC 400 V, -5%)
P
max
kW
ca. 26
ca. 55
Continuous regenerated power
P
rück
kW
ca. 22
ca. 30
Peak regenerated power (max. 10 s) (as
relates to the driven shaft of motor)
P
rückmax
kW
ca. 26
ca. 55
Drive controller power voltage
U
eff
V
0 ... 380
max. frequency of the power voltage
(4 kHz/8 kHz)*
f
max
Hz
4 kHz: 800
8 kHz: 1600
Total heat dissipation at I
conteff
P
Vges
W
900
1200
Heat dissipation in air channel or with
coolant at I
conteff
P
Vext
W
600
800
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01