© Welbilt, Inc.
Alert Log and Service Definition
130
Indigo NXT Ice Machine Troubleshooting Tips
When an Alert / E Log is triggered;
• Alerts shows up on the Home screen
as an Alert Icon.
•Alerts are also kept track of on what
we call “Alert Log”.
•Alert Log list time stamp of last Alert
along with count of how many times it
has tripped. Still visible in the Service
Menu, even if the Alert was cleared by
the end-user from the Home Screen.
E-Log Display Text
Error Description
Definition
E01
Long Freeze
Long Freeze
3 consecutive 35 Minute Freeze cycle, shut down
E02
Long Harvest
Long Harvest
3 - 7 Minute Harvests logs SL#2 in memory but doesn't shut down until 500 long harvest cycles.
E03
Power Loss
Power Supply (Event
Log only - No Alarm)
When power is interrupted to the ice machine the control board will log the event in the ELOG and stamp the loss of
power on power-up.
E04
Hi Cnd Temp or Wtr
Cnd Fault
Air Condenser High
temp, or water
Condenser High
temperature
1). Air Cooled Condenser Fault = Liquid Line Temperature too Hi for Selfcontained Air Cooled Ice machine.
2). Water Cooled Condenser Fault = Liquid Line Temperature too Hi for Selfcontained Water Cooled Ice machine.
(G-board rev 4.017 forward: Alert
E05
HPC Fault
High Pressure Cutout
(HPC)
The high pressure cutout switch (HPCO) opened.
Alert will show after 3 trips in 4 hours.
E06
Spare
E07
Starving TXV
Starving Evaporator for
single TXV or low on
charge
When harvest is initiated by the ITP: the board compares the last one minute of Freeze average temperature
difference between the inlet (T3) and the outlet (T4). If the difference between the outlet minus the inlet is greater
than 12°F E07 is recorded.
E08
TXV Fault
TXV malfunction in dual
circuit/ single evaps
(TXV Fault)
When harvest is initiated by the ITP: the board compares the last one minute of Freeze average temperature
difference between the outlet (T3) and the outlet (T4). If the difference between the outlet minus the inlet is greater
than 12°F E07 is recorded.
E09
Flood Evap 1
Flooding evaporator for
single circuit single
evaporator (flooding
evap)
Discharged line temp. is monitored in 6 second increments for the first 6 min. of freeze. Each minute is averaged
and the highest average is stored as T2max(3). During the last 6 seconds of pre chill the liquid line temp exiting the
condenser is averaged
E10
Flood Evap 2
Flooding evaporator for
dual TXV dual circuit /
single evaporator
(Flooding Evap)
Discharged line temp. is monitored in 6 second increments for the first 6 min. of freeze. Each minute is averaged
and the highest average is stored as T2max(3). During the last 6 seconds of pre chill the liquid line temp exiting the
condenser is averaged
E11
Refig Fault
(Air, Water only)
Refrigeration System
(Refrig Fault)
If the compressor discharge temperature has not increased by at least 10 F, and the evaporator temperature has
not decreased by at least 10 F from the Refrigeration Start up or start of prechill to Two Minutes into the Freeze
cycle.
(G-board rev 4.017 f
E12
Curtain Fault
Curtain Switch open for
more than 12 hours
(Curtain Fault)
If the ice machine is set in an ice making position and in bin full condition for more than 12 hours then the curtain
switch is open or curtain is off.
(12 hrs all E- Boards / 24 hrs G-Boards after revision 4.017)
E13
Spare
E14
Spare
E15
Low Liq Temp
Low amb control fault
durring low amb
If the liquid line temperature drops below 60 F for any period exceeding 1 continuous minute during the freeze cycle.
(G-board rev 4.017 forward: Event log only-no alert)
Detail Alert Log Service Definition
Содержание Welbilt Indigo NXT QuietQube
Страница 3: ... Welbilt Inc Welbilt Inc Engineered For Ease Overview INDIGO NXT 3 ...
Страница 17: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube CVD Installation INDIGO NXT 17 ...
Страница 32: ... Welbilt Inc Welbilt Inc Engineered For Ease EasyTouch Installation Set Up Wizard INDIGO NXT Ice Machine 32 ...
Страница 50: ... Welbilt Inc Engineered For Ease Menu Navigation Indigo NXT Ice Machines ...
Страница 54: ... Welbilt Inc Indigo NXT Menu Navigation Alert 54 Touch Screen Interface Main Menu ...
Страница 55: ... Welbilt Inc Indigo NXT Menu Navigation Alert 55 Touch Screen Interface Main Menu ...
Страница 71: ... Welbilt Inc Welbilt Inc Engineered For Ease Sequence of Operation QuietQube CVD INDIGO NXT Ice Machines 71 ...
Страница 72: ... Welbilt Inc Remote IB CVD Ice machines 72 Indigo NXT QuietQube CVD Sequence of Operation Bin Probe ...
Страница 101: ... Welbilt Inc Welbilt Inc Engineered For Ease QuietQube Remote CVD Refrigeration System INDIGO NXT Ice Machine 101 ...
Страница 114: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting INDIGO NXT Ice Machine 114 ...
Страница 125: ... Welbilt Inc Review 125 Symptom 1 Symptom 2 Symptom 3 Air Water Traditional Remote QuietQube Symptom 4 ...
Страница 126: ... Welbilt Inc Welbilt Inc Engineered For Ease Troubleshooting Tips INDIGO NXT Ice Machine 126 ...
Страница 153: ... Welbilt Inc Water Level Probe Diagnostics 153 Indigo NXT Ice Machine Troubleshooting Tips ...